CVE-2025-34195
Vasion Print (formerly PrinterLogic) Unquoted Path During Driver Installation Leads to Execution of C:\Program.exe
Vasion Print (formerly PrinterLogic) Virtual Appliance Host versions prior to 1.0.735 and Application prior to 20.0.1330 (Windows client deployments) contain a remote code execution vulnerability during driver installation caused by unquoted program paths. The PrinterInstallerClient driver-installation component launches programs using an unquoted path under "C:\Program Files (x86)\Printer Properties Pro\Printer Installer". Because the path is unquoted, the operating system may execute a program located at a short-path location such as C:\Program.exe before the intended binaries in the quoted path. If an attacker can place or cause a program to exist at that location, it will be executed with the privileges of the installer process (which may be elevated), enabling arbitrary code execution and potential privilege escalation. This weakness can be used to achieve remote code execution and full compromise of affected Windows endpoints. This vulnerability has been identified by the vendor as: V-2022-006 — Driver Upload Security.
Attack profile
How easy it is to exploit
- Attack vector
- Local
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used
8.6
Vasion Print (formerly PrinterLogic) Unquoted Path During Driver Installation Leads to Execution of C:\Program.exe
Vasion Print (formerly PrinterLogic) Virtual Appliance Host versions prior to 1.0.735 and Application prior to 20.0.1330 (Windows client deployments) contain a remote code execution vulnerability during driver installation caused by unquoted program paths. The PrinterInstallerClient driver-installation component launches programs using an unquoted path under "C:\Program Files (x86)\Printer Properties Pro\Printer Installer". Because the path is unquoted, the operating system may execute a program located at a short-path location such as C:\Program.exe before the intended binaries in the quoted path. If an attacker can place or cause a program to exist at that location, it will be executed with the privileges of the installer process (which may be elevated), enabling arbitrary code execution and potential privilege escalation. This weakness can be used to achieve remote code execution and full compromise of affected Windows endpoints. This vulnerability has been identified by the vendor as: V-2022-006 — Driver Upload Security.
- Record
CVE-2025-34195- CVSS 4.0
- 8.6 High
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N - Weakness
- CWE-434
- Updated
- 2026-11-02
EUVDEUVD-2025-30265
8.6
Vasion Print (formerly PrinterLogic) Virtual Appliance Host versions prior to 1.0.735 and Application prior to 20.0.1330 (Windows client deployments) contain a remote code execution vulnerability during driver installation caused by unquoted program paths. The PrinterInstallerClient driver-installation component launches programs using an unquoted path under "C:\Program Files (x86)\Printer Properties Pro\Printer Installer". Because the path is unquoted, the operating system may execute a program located at a short-path location such as C:\Program.exe before the intended binaries in the quoted path. If an attacker can place or cause a program to exist at that location, it will be executed with the privileges of the installer process (which may be elevated), enabling arbitrary code execution and potential privilege escalation. This weakness can be used to achieve remote code execution and full compromise of affected Windows endpoints. This vulnerability has been identified by the vendor as: V-2022-006 — Driver Upload Security.
- Record
EUVD-2025-30265- CVSS 4.0
- 8.6 High
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-5g4v-r3ch-wg6m
8.6
Vasion Print (formerly PrinterLogic) Virtual Appliance Host versions prior to 1.0.735 and...
Vasion Print (formerly PrinterLogic) Virtual Appliance Host versions prior to 1.0.735 and Application prior to 20.0.1330 (Windows client deployments) contain a remote code execution vulnerability during driver installation caused by unquoted program paths. The PrinterInstallerClient driver-installation component launches programs using an unquoted path under "C:\Program Files (x86)\Printer Properties Pro\Printer Installer". Because the path is unquoted, the operating system may execute a program located at a short-path location such as C:\Program.exe before the intended binaries in the quoted path. If an attacker can place or cause a program to exist at that location, it will be executed with the privileges of the installer process (which may be elevated), enabling arbitrary code execution and potential privilege escalation. This weakness can be used to achieve remote code execution and full compromise of affected Windows endpoints.
- Record
GHSA-5g4v-r3ch-wg6m- CVSS 4.0
- 8.6 High
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X - CVSS 3.1
- 9.8 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-434
- Updated
- 2026-11-02
NVD
8.6
Vasion Print (formerly PrinterLogic) Virtual Appliance Host versions prior to 1.0.735 and Application prior to 20.0.1330 (Windows client deployments) contain a remote code execution vulnerability during driver installation caused by unquoted program paths. The PrinterInstallerClient driver-installation component launches programs using an unquoted path under "C:\Program Files (x86)\Printer Properties Pro\Printer Installer". Because the path is unquoted, the operating system may execute a program located at a short-path location such as C:\Program.exe before the intended binaries in the quoted path. If an attacker can place or cause a program to exist at that location, it will be executed with the privileges of the installer process (which may be elevated), enabling arbitrary code execution and potential privilege escalation. This weakness can be used to achieve remote code execution and full compromise of affected Windows endpoints. This vulnerability has been identified by the vendor as: V-2022-006 — Driver Upload Security.
- Record
CVE-2025-34195- CVSS 4.0
- 8.6 High
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X - CVSS 3.1
- 9.8 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-434
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2025-34195 is a high vulnerability (CVSS 8.6) in Vasion Virtual Appliance Host, published September 19, 2025. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.97%, the 62nd percentile. No source names a fixed version.
References
help.printerlogic.com/saas/Print/Security/Security-Bulletins.htm
pierrekim.github.io/blog/2025-04-08-vasion-printerlogic-83-vulnerabilities.html
help.printerlogic.com/va/Print/Security/Security-Bulletins.htm
vulncheck.com/advisories/vasion-print-printerlogic-unquoted-path-during-driver-installation
nvd.nist.gov/vuln/detail/CVE-2025-34195
github.com/advisories/GHSA-5g4v-r3ch-wg6m