Every CVE Search/ Get API key

CVE-2025-3511

Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric...

7.5 High

Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY, MELSEC iQ-R Series CC-Link IE TSN Master/Local Module, MELSEC iQ-R Series Ethernet Interface Module, CC-Link IE TSN Master/Local Station Communication LSI CP610, MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module, MELSEC iQ-F Series FX5 Ethernet Module, MELSEC iQ-F Series FX5-ENET/IP Ethernet Module, and MELSEC iQ-R Series CPU module allows a remote unauthenticated attacker to cause a Denial of Service condition in the products by sending specially crafted UDP packets.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
None
Integrity
None
Availability
High

Exploit likelihood

0.93%Up 0.9 points since Apr 25, 2025
90%50%10%1%

What each source reports

CVE List Score used 7.5

Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY, MELSEC iQ-R Series CC-Link IE TSN Master/Local Module, MELSEC iQ-R Series Ethernet Interface Module, CC-Link IE TSN Master/Local Station Communication LSI CP610, MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module, MELSEC iQ-F Series FX5 Ethernet Module, MELSEC iQ-F Series FX5-ENET/IP Ethernet Module, and MELSEC iQ-R Series CPU module allows a remote unauthenticated attacker to cause a Denial of Service condition in the products by sending specially crafted UDP packets.

Record
CVE-2025-3511
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Weakness
CWE-1284
Updated
2026-11-02
EUVDEUVD-2025-12400 7.5

Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY, MELSEC iQ-R Series CC-Link IE TSN Master/Local Module, MELSEC iQ-R Series Ethernet Interface Module, CC-Link IE TSN Master/Local Station Communication LSI CP610, MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module, MELSEC iQ-F Series FX5 Ethernet Module, MELSEC iQ-F Series FX5-ENET/IP Ethernet Module, and MELSEC iQ-R Series CPU module allows a remote unauthenticated attacker to cause a Denial of Service condition in the products by sending specially crafted UDP packets.

Record
EUVD-2025-12400
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Updated
2026-11-02
GitHub AdvisoriesGHSA-f46p-qr4h-m6p4 5.9

Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric...

Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module and CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY allows a remote unauthenticated attacker to cause a Denial of Service condition in the products by sending specially crafted UDP packets.

Record
GHSA-f46p-qr4h-m6p4
CVSS 3.1
5.9 MediumCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H
Weakness
CWE-1284
Updated
2026-11-02
NVD 7.5

Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric Corporation CC-Link IE TSN Remote I/O module, CC-Link IE TSN Analog-Digital Converter module, CC-Link IE TSN Digital-Analog Converter module, CC-Link IE TSN FPGA module, CC-Link IE TSN Remote Station Communication LSI CP620 with GbE-PHY, MELSEC iQ-R Series CC-Link IE TSN Master/Local Module, MELSEC iQ-R Series Ethernet Interface Module, CC-Link IE TSN Master/Local Station Communication LSI CP610, MELSEC iQ-F Series FX5 CC-Link IE TSN Master/Local Module, MELSEC iQ-F Series FX5 Ethernet Module, MELSEC iQ-F Series FX5-ENET/IP Ethernet Module, and MELSEC iQ-R Series CPU module allows a remote unauthenticated attacker to cause a Denial of Service condition in the products by sending specially crafted UDP packets.

Record
CVE-2025-3511
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Weakness
CWE-1284
Updated
2026-11-02

Affected products

Show 37 moreShow less

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2025-3511 is a high vulnerability (CVSS 7.5) in Mitsubishi Electric Corporation Cc-link Ie Tsn Analog-digital Converter Module Nz2gn2b-60ad4, published April 25, 2025. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.93%, the 60th percentile. No source names a fixed version.

References

MoveEnter Open