CVE-2025-36595
Dell Unisphere for PowerMax vApp, version(s) 9.2.4.x, contain(s) an Improper Neutralization of...
Dell Unisphere for PowerMax vApp, version(s) 9.2.4.x, contain(s) an Improper Neutralization of Directives in Statically Saved Code ('Static Code Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Code execution.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- High
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used
7.2
Dell Unisphere for PowerMax vApp, version(s) 9.2.4.x, contain(s) an Improper Neutralization of Directives in Statically Saved Code ('Static Code Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Code execution.
- Record
CVE-2025-36595- CVSS 3.1
- 7.2 High
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-96
- Updated
- 2026-11-02
EUVDEUVD-2025-19348
7.2
Dell Unisphere for PowerMax vApp, version(s) 9.2.4.x, contain(s) an Improper Neutralization of Directives in Statically Saved Code ('Static Code Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Code execution.
- Record
EUVD-2025-19348- CVSS 3.1
- 7.2 High
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-7886-36j3-hr33
7.2
Dell Unisphere for PowerMax vApp, version(s) 9.2.4.x, contain(s) an Improper Neutralization of...
Dell Unisphere for PowerMax vApp, version(s) 9.2.4.x, contain(s) an Improper Neutralization of Directives in Statically Saved Code ('Static Code Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Code execution.
- Record
GHSA-7886-36j3-hr33- CVSS 3.1
- 7.2 High
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-96
- Updated
- 2026-11-02
NVD
7.2
Dell Unisphere for PowerMax vApp, version(s) 9.2.4.x, contain(s) an Improper Neutralization of Directives in Statically Saved Code ('Static Code Injection') vulnerability. A high privileged attacker with remote access could potentially exploit this vulnerability, leading to Code execution.
- Record
CVE-2025-36595- CVSS 3.1
- 7.2 High
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-96
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2025-36595 is a high vulnerability (CVSS 7.2) in Dell Unisphere For Powermax Vapp, published June 27, 2025. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.65%, the 51st percentile. No source names a fixed version.
References
dell.com/support/kbdoc/en-us/000337554/dsa-2025-235-dell-powermaxos-dell-powermax-eem-dell-unisphere-for-powermax-dell-unisphere-for-powermax-virtual-appliance-dell-unisphere-360-dell-solutions-enabler-and-dell-solutions-enabler-virtual-appliance-security-update-for-multiple-vulnerabilit
nvd.nist.gov/vuln/detail/CVE-2025-36595
github.com/advisories/GHSA-7886-36j3-hr33