Every CVE Search/ Get API key

CVE-2025-3905

CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')...

5.1 Medium

CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists impacting PLC system variables that could cause an unvalidated data injected by authenticated malicious user leading to modify or read data in a victim’s browser.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
Low
User interaction
Passive

What an attacker can affect

Confidentiality
None
Integrity
Low
Availability
None

Exploit likelihood

0.32%Up 0.3 points since Jun 10, 2025
90%50%10%1%

What each source reports

CVE List Score used 5.1

CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists impacting PLC system variables that could cause an unvalidated data injected by authenticated malicious user leading to modify or read data in a victim’s browser.

Record
CVE-2025-3905
CVSS 4.0
5.1 MediumCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:L/SI:L/SA:N
CVSS 3.1
5.4 MediumCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
Weakness
CWE-79
Updated
2026-11-02
EUVDEUVD-2025-17646 5.1

CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists impacting PLC system variables that could cause an unvalidated data injected by authenticated malicious user leading to modify or read data in a victim’s browser.

Record
EUVD-2025-17646
CVSS 4.0
5.1 MediumCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:L/SI:L/SA:N
Updated
2026-11-02
GitHub AdvisoriesGHSA-x3hv-q6h3-h9ph 5.1

CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')...

CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists impacting PLC system variables that could cause an unvalidated data injected by authenticated malicious user leading to modify or read data in a victim’s browser.

Record
GHSA-x3hv-q6h3-h9ph
CVSS 4.0
5.1 MediumCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
5.4 MediumCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
Weakness
CWE-79
Updated
2026-11-02
NVD 5.1

CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists impacting PLC system variables that could cause an unvalidated data injected by authenticated malicious user leading to modify or read data in a victim’s browser.

Record
CVE-2025-3905
CVSS 4.0
5.1 MediumCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:N/VI:L/VA:N/SC:L/SI:L/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
5.4 MediumCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N
Weakness
CWE-79
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2025-3905 is a medium vulnerability (CVSS 5.1) in Schneider Electric Modicon Controllers M241/m251, published June 10, 2025. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.32%, the 24th percentile. No source names a fixed version.

References