Every CVE Search/ Get API key

CVE-2025-39202

A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. An...

8.3 High

A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. An authenticated user with low privileges can see and overwrite files causing information leak and data corruption.

Attack profile

How easy it is to exploit

Attack vector
Local
Complexity
Low
Privileges needed
Low
User interaction
None

What an attacker can affect

Confidentiality
Low
Integrity
High
Availability
High

Exploit likelihood

0.23%Up 0.2 points since Jun 24, 2025
90%50%10%1%

What each source reports

CVE List Score used 8.3

A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. An authenticated user with low privileges can see and overwrite files causing information leak and data corruption.

Record
CVE-2025-39202
CVSS 4.0
8.3 HighCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:H/VA:H/SC:N/SI:H/SA:H
CVSS 3.1
7.3 HighCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:H
Weakness
CWE-269
Updated
2026-11-02
EUVDEUVD-2025-19003 8.3

A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. An authenticated user with low privileges can see and overwrite files causing information leak and data corruption.

Record
EUVD-2025-19003
CVSS 4.0
8.3 HighCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:H/VA:H/SC:N/SI:H/SA:H
Updated
2026-11-02
GitHub AdvisoriesGHSA-x764-54fg-9f42 8.3

A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. An...

A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. An authenticated user with low privileges can see and overwrite files causing information leak and data corruption.

Record
GHSA-x764-54fg-9f42
CVSS 4.0
8.3 HighCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:H/VA:H/SC:N/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
7.3 HighCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:H
Weakness
CWE-269
Updated
2026-11-02
NVD 8.3

A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. An authenticated user with low privileges can see and overwrite files causing information leak and data corruption.

Record
CVE-2025-39202
CVSS 4.0
8.3 HighCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:H/VA:H/SC:N/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
7.3 HighCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:H
CVSS 3.1
8.1 HighCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N
Weakness
CWE-269
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2025-39202 is a high vulnerability (CVSS 8.3) in Hitachi Energy Microscada X Sys600, published June 24, 2025. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.23%, the 14th percentile. No source names a fixed version.

References

MoveEnter Open