Every CVE Search/ Get API key

CVE-2025-48709

BMC Control-M/Server cleartext database credentials in process lists and logs

4.8 Medium

BMC Control-M/Server 9.0.21.300 displays cleartext database credentials in process lists and logs. An authenticated attacker with shell access could observe these credentials and use them to log in to the database server. For example, when Control-M/Server on Windows has a database connection on, it runs 'DBUStatus.exe' frequently, which then calls 'dbu_connection_details.vbs' with the username, password, database hostname, and port written in cleartext, which can be seen in event and process logs in two separate locations. Fixed in PACTV.9.0.21.307.

Attack profile

How easy it is to exploit

Attack vector
Local
Complexity
Low
Privileges needed
Low
User interaction
None

What an attacker can affect

Confidentiality
Low
Integrity
None
Availability
None

Exploit likelihood

0.13%Up 0.1 points since Aug 8, 2025
90%50%10%1%

What each source reports

CVE List Score used 4.8

BMC Control-M/Server cleartext database credentials in process lists and logs

BMC Control-M/Server 9.0.21.300 displays cleartext database credentials in process lists and logs. An authenticated attacker with shell access could observe these credentials and use them to log in to the database server. For example, when Control-M/Server on Windows has a database connection on, it runs 'DBUStatus.exe' frequently, which then calls 'dbu_connection_details.vbs' with the username, password, database hostname, and port written in cleartext, which can be seen in event and process logs in two separate locations. Fixed in PACTV.9.0.21.307.

Record
CVE-2025-48709
CVSS 4.0
4.8 MediumCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N
CVSS 3.1
3.8 LowCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N
Weakness
CWE-532, CWE-214
Updated
2026-11-02
EUVDEUVD-2025-23950 4.8

BMC Control-M/Server 9.0.21.300 displays cleartext database credentials in process lists and logs. An authenticated attacker with shell access could observe these credentials and use them to log in to the database server. For example, when Control-M/Server on Windows has a database connection on, it runs 'DBUStatus.exe' frequently, which then calls 'dbu_connection_details.vbs' with the username, password, database hostname, and port written in cleartext, which can be seen in event and process logs in two separate locations. Fixed in PACTV.9.0.21.307.

Record
EUVD-2025-23950
CVSS 4.0
4.8 MediumCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N
Updated
2026-11-02
GitHub AdvisoriesGHSA-cgj5-r57f-xw42 4.8

An issue was discovered in BMC Control-M 9.0.21.300. When Control-M Server has a database...

An issue was discovered in BMC Control-M 9.0.21.300. When Control-M Server has a database connection, it runs DBUStatus.exe frequently, which then calls dbu_connection_details.vbs with the username, password, database hostname, and port written in cleartext, which can be seen in event and process logs in two separate locations.

Record
GHSA-cgj5-r57f-xw42
CVSS 4.0
4.8 MediumCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-214, CWE-522, CWE-532
Updated
2026-11-02
NVD 4.8

BMC Control-M/Server 9.0.21.300 displays cleartext database credentials in process lists and logs. An authenticated attacker with shell access could observe these credentials and use them to log in to the database server. For example, when Control-M/Server on Windows has a database connection on, it runs 'DBUStatus.exe' frequently, which then calls 'dbu_connection_details.vbs' with the username, password, database hostname, and port written in cleartext, which can be seen in event and process logs in two separate locations. Fixed in PACTV.9.0.21.307.

Record
CVE-2025-48709
CVSS 4.0
4.8 MediumCVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
3.8 LowCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N
CVSS 3.1
7.8 HighCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-214, CWE-532, CWE-522
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2025-48709 is a medium vulnerability (CVSS 4.8) in Bmc Control-m, published August 7, 2025. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.13%, the 2nd percentile. No source names a fixed version.

References

MoveEnter Open