Every CVE Search/ Get API key

CVE-2025-54818

Cognex In-Sight Explorer and In-Sight Camera Firmware Cleartext Transmission of Sensitive Information

8.6 High

Cognex In-Sight Explorer and In-Sight Camera Firmware expose

a proprietary protocol on TCP port 1069 to perform management operations such as modifying system properties. The user management functionality handles sensitive data such as registered usernames and passwords over an unencrypted channel, allowing an adjacent attacker to intercept valid credentials to gain access to the device.

Attack profile

How easy it is to exploit

Attack vector
Adjacent network
Complexity
Low
Privileges needed
None
User interaction
Passive

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

0.15%Up 0.1 points since Sep 19, 2025
90%50%10%1%

What each source reports

CVE List Score used 8.6

Cognex In-Sight Explorer and In-Sight Camera Firmware Cleartext Transmission of Sensitive Information

Cognex In-Sight Explorer and In-Sight Camera Firmware expose

a proprietary protocol on TCP port 1069 to perform management operations such as modifying system properties. The user management functionality handles sensitive data such as registered usernames and passwords over an unencrypted channel, allowing an adjacent attacker to intercept valid credentials to gain access to the device.

Record
CVE-2025-54818
CVSS 4.0
8.6 HighCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CVSS 3.1
8.0 HighCVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Weakness
CWE-319
Updated
2026-11-02
EUVDEUVD-2025-30229 8.6

Cognex In-Sight Explorer and In-Sight Camera Firmware expose

a proprietary protocol on TCP port 1069 to perform management operations such as modifying system properties. The user management functionality handles sensitive data such as registered usernames and passwords over an unencrypted channel, allowing an adjacent attacker to intercept valid credentials to gain access to the device.

Record
EUVD-2025-30229
CVSS 4.0
8.6 HighCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Updated
2026-11-02
GitHub AdvisoriesGHSA-87gj-4m36-p6h7 8.6

Cognex In-Sight Explorer and In-Sight Camera Firmware expose a proprietary protocol on TCP port...

Cognex In-Sight Explorer and In-Sight Camera Firmware expose

a proprietary protocol on TCP port 1069 to perform management operations such as modifying system properties. The user management functionality handles sensitive data such as registered usernames and passwords over an unencrypted channel, allowing an adjacent attacker to intercept valid credentials to gain access to the device.

Record
GHSA-87gj-4m36-p6h7
CVSS 4.0
8.6 HighCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
8.0 HighCVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Weakness
CWE-319
Updated
2026-11-02
NVD 8.6

Cognex In-Sight Explorer and In-Sight Camera Firmware expose

a proprietary protocol on TCP port 1069 to perform management operations such as modifying system properties. The user management functionality handles sensitive data such as registered usernames and passwords over an unencrypted channel, allowing an adjacent attacker to intercept valid credentials to gain access to the device.

Record
CVE-2025-54818
CVSS 4.0
8.6 HighCVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
8.0 HighCVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Weakness
CWE-319
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2025-54818 is a high vulnerability (CVSS 8.6) in Cognex In-sight Explorer, published September 18, 2025. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.15%, the 3rd percentile. No source names a fixed version.

References

MoveEnter Open