CVE-2025-59171

Advantech DeviceOn/iEdge Path Traversal

8.7 High

Due to insufficient sanitization, an attacker can upload a specially crafted configuration file to traverse directories and achieve remote code execution with system-level permissions.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
None
Availability
None

Exploit likelihood

0.76%Up 0.7 points since Nov 7, 2025
90%50%10%1%

What each source reports

CVE List Score used 8.7

Advantech DeviceOn/iEdge Path Traversal

Due to insufficient sanitization, an attacker can upload a specially crafted configuration file to traverse directories and achieve remote code execution with system-level permissions.

Record
CVE-2025-59171
CVSS 4.0
8.7 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Weakness
CWE-22, CWE-22
Updated
2026-11-02
EUVDEUVD-2025-38199 8.7

Due to insufficient sanitization, an attacker can upload a specially crafted configuration file to traverse directories and achieve remote code execution with system-level permissions.

Record
EUVD-2025-38199
CVSS 4.0
8.7 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N
Updated
2026-11-02
GitHub AdvisoriesGHSA-22f5-36q8-782w 8.7

Due to insufficient sanitization, an attacker can upload a specially crafted configuration file...

Due to insufficient sanitization, an attacker can upload a specially crafted configuration file to traverse directories and achieve remote code execution with system-level permissions.

Record
GHSA-22f5-36q8-782w
CVSS 4.0
8.7 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Weakness
CWE-22
Updated
2026-11-02
NVD 8.7

Due to insufficient sanitization, an attacker can upload a specially crafted configuration file to traverse directories and achieve remote code execution with system-level permissions.

Record
CVE-2025-59171
CVSS 4.0
8.7 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-22
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2025-59171 is a high vulnerability (CVSS 8.7) in Advantech Deviceon/iedge, published November 6, 2025. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.76%, the 55th percentile. No source names a fixed version.

References