Every CVE Search/ Get API key

CVE-2025-5946

RCE via the poller reload feature available only to user with high privilege

7.2 HighPublic exploit

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection. On the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command.

This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
High
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

13.5%Up 13.4 points since Oct 15, 2025
90%50%10%1%

What each source reports

CVE List Score used 7.2

RCE via the poller reload feature available only to user with high privilege

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection. On the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command.

This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.

Record
CVE-2025-5946
CVSS 3.1
7.2 HighCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-78
Updated
2026-11-02
EUVDEUVD-2025-34208 7.2

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection. On the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command.

This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.

Record
EUVD-2025-34208
CVSS 3.1
7.2 HighCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Updated
2026-11-02
GitHub AdvisoriesGHSA-mpw2-f23v-c9fv 7.2

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')...

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection. On the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command.

This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.

Record
GHSA-mpw2-f23v-c9fv
CVSS 3.1
7.2 HighCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-78
Updated
2026-11-02
NVD 7.2

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection. On the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command.

This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.

Record
CVE-2025-5946
CVSS 3.1
7.2 HighCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-78
Updated
2026-11-02
OSV 7.2

RCE via the poller reload feature available only to user with high privilege

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection. On the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command.

This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.

Record
CVE-2025-5946
CVSS 3.1
7.2 HighCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-78
Updated
2026-11-02

Affected products

Public exploits

Links only. Every CVE stores no exploit code.

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, Metasploit, NVD, OSV

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2025-5946 is a high vulnerability (CVSS 7.2) in Centreon Infra Monitoring, published October 14, 2025. Public exploit code exists. EPSS puts the chance of exploitation in the next 30 days at 13.5%, the 96th percentile. No source names a fixed version.

References

MoveEnter Open