CVE-2025-59703
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a...
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allow a Physically Proximate Attacker to access the internal components of the appliance, without leaving tamper evidence. To exploit this, the attacker needs to remove the tamper label and all fixing screws from the device without damaging it. This is called an F14 attack.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- None
Exploit likelihood
What each source reports
CVE List Score used
9.1
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allow a Physically Proximate Attacker to access the internal components of the appliance, without leaving tamper evidence. To exploit this, the attacker needs to remove the tamper label and all fixing screws from the device without damaging it. This is called an F14 attack.
- Record
CVE-2025-59703- CVSS 3.1
- 9.1 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N - Weakness
- CWE-284
- Updated
- 2026-11-02
EUVDEUVD-2025-200272
9.1
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allow a Physically Proximate Attacker to access the internal components of the appliance, without leaving tamper evidence. To exploit this, the attacker needs to remove the tamper label and all fixing screws from the device without damaging it. This is called an F14 attack.
- Record
EUVD-2025-200272- CVSS 3.1
- 9.1 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-h78c-68qv-3qg9
9.1
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a...
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allow a Physically Proximate Attacker to access the internal components of the appliance, without leaving tamper evidence. To exploit this, the attacker needs to remove the tamper label and all fixing screws from the device without damaging it. This is called an F14 attack.
- Record
GHSA-h78c-68qv-3qg9- CVSS 3.1
- 9.1 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N - Weakness
- CWE-284
- Updated
- 2026-11-02
NVD
9.1
Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7 (patched in 13.6.12 (LTS) and 13.9.0 (STS)), allow a Physically Proximate Attacker to access the internal components of the appliance, without leaving tamper evidence. To exploit this, the attacker needs to remove the tamper label and all fixing screws from the device without damaging it. This is called an F14 attack.
- Record
CVE-2025-59703- CVSS 3.1
- 9.1 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N - Weakness
- CWE-284
- Updated
- 2026-11-05
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| facts | NVD | |
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2025-59703 is a critical vulnerability (CVSS 9.1) in Entrust Nshield 5c Firmware, published December 2, 2025. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.50%, the 43rd percentile. No source names a fixed version.