CVE-2025-66052
Command injection in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default, The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- High
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used
8.6
Command injection in Vivotek IP7137 cameras
Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default, The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
- Record
CVE-2025-66052- CVSS 4.0
- 8.6 High
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N - Weakness
- CWE-78
- Updated
- 2026-11-02
EUVDEUVD-2026-1748
8.6
Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default, The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
- Record
EUVD-2026-1748- CVSS 4.0
- 8.6 High
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-6hj7-3vmc-gm54
8.6
Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter ...
Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default, The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
- Record
GHSA-6hj7-3vmc-gm54- CVSS 4.0
- 8.6 High
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X - CVSS 3.1
- 7.2 High
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-78
- Updated
- 2026-11-02
NVD
8.6
Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default, The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
- Record
CVE-2025-66052- CVSS 4.0
- 8.6 High
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X - CVSS 3.1
- 7.2 High
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-78
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2025-66052 is a high vulnerability (CVSS 8.6) in Vivotek Ip7137, published January 9, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.49%, the 74th percentile. No source names a fixed version.