CVE-2025-6678
Autel MaxiCharger AC Wallbox Commercial PIN Missing Authentication Information Disclosure Vulnerability
Autel MaxiCharger AC Wallbox Commercial PIN Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the Pile API. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose credentials, leading to further compromise. Was ZDI-CAN-26352.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- None
- Availability
- None
Exploit likelihood
What each source reports
CVE List Score used
7.5
Autel MaxiCharger AC Wallbox Commercial PIN Missing Authentication Information Disclosure Vulnerability
Autel MaxiCharger AC Wallbox Commercial PIN Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the Pile API. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose credentials, leading to further compromise. Was ZDI-CAN-26352.
- Record
CVE-2025-6678- CVSS 3.0
- 7.5 High
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N - Weakness
- CWE-306
- Updated
- 2026-11-02
EUVDEUVD-2025-28757
7.5
Autel MaxiCharger AC Wallbox Commercial PIN Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the Pile API. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose credentials, leading to further compromise. Was ZDI-CAN-26352.
- Record
EUVD-2025-28757- CVSS 3.0
- 7.5 High
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-9rgw-7fg2-wjgr
7.5
Autel MaxiCharger AC Wallbox Commercial PIN Missing Authentication Information Disclosure...
Autel MaxiCharger AC Wallbox Commercial PIN Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the Pile API. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose credentials, leading to further compromise. Was ZDI-CAN-26352.
- Record
GHSA-9rgw-7fg2-wjgr- CVSS 3.0
- 7.5 High
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N - Weakness
- CWE-306
- Updated
- 2026-11-02
NVD
7.5
Autel MaxiCharger AC Wallbox Commercial PIN Missing Authentication Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the Pile API. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to disclose credentials, leading to further compromise. Was ZDI-CAN-26352.
- Record
CVE-2025-6678- CVSS 3.0
- 7.5 High
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N - Weakness
- CWE-306
- Updated
- 2026-11-02
Affected products
- autel maxicharger ac wallbox commercial
- autel maxicharger ac elite business c50 firmware
- autel maxicharger ac pro firmware
- autel maxicharger ac ultra firmware
- autel maxicharger dc compact mobile firmware
- autel maxicharger dc compact pedestal firmware
- autel maxicharger dc fast firmware
- autel maxicharger dc hipower firmware
- autel maxicharger dh480 firmware
- autel maxicharger single charger firmware
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2025-6678 is a high vulnerability (CVSS 7.5) in Autel Maxicharger Ac Wallbox Commercial, published June 25, 2025. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.48%, the 41st percentile. No source names a fixed version.