CVE-2025-9483
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 singlePortForwardAdd stack-based overflow
A flaw has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected is the function singlePortForwardAdd of the file /goform/singlePortForwardAdd. This manipulation of the argument ruleName/schedule/inboundFilter causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used
8.7
Linksys RE6250/RE6300/RE6350/RE6500/RE7000/RE9000 singlePortForwardAdd stack-based overflow
A flaw has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected is the function singlePortForwardAdd of the file /goform/singlePortForwardAdd. This manipulation of the argument ruleName/schedule/inboundFilter causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
- Record
CVE-2025-9483- CVSS 4.0
- 8.7 High
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P - CVSS 3.1
- 8.8 High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R - CVSS 3.0
- 8.8 High
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R - CVSS 2.0
- 9.0
AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR - Weakness
- CWE-121, CWE-119
- Updated
- 2026-11-02
EUVDEUVD-2025-25779
8.7
A flaw has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected is the function singlePortForwardAdd of the file /goform/singlePortForwardAdd. This manipulation of the argument ruleName/schedule/inboundFilter causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
- Record
EUVD-2025-25779- CVSS 4.0
- 8.7 High
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-prm8-g25g-2935
7.4
A flaw has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1...
A flaw has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected is the function singlePortForwardAdd of the file /goform/singlePortForwardAdd. This manipulation of the argument ruleName/schedule/inboundFilter causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
- Record
GHSA-prm8-g25g-2935- CVSS 4.0
- 7.4 High
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X - CVSS 3.1
- 8.8 High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-119
- Updated
- 2026-11-02
NVD
7.4
A flaw has been found in Linksys RE6250, RE6300, RE6350, RE6500, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected is the function singlePortForwardAdd of the file /goform/singlePortForwardAdd. This manipulation of the argument ruleName/schedule/inboundFilter causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
- Record
CVE-2025-9483- CVSS 4.0
- 7.4 High
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X - CVSS 3.1
- 8.8 High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 9.0 High
AV:N/AC:L/Au:S/C:C/I:C/A:C - Weakness
- CWE-119, CWE-121
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2025-9483 is a high vulnerability (CVSS 8.7) in Linksys Re6250, published August 26, 2025. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.05%, the 64th percentile. No source names a fixed version.