CVE-2026-126622
Incorrect Default Permissions in hMailServer
Incorrect default permissions in the Windows installer of Progressive Robot hMailServer 6.3.7 allow a local authenticated user to run code as the administrator who runs setup, when the server is installed into a program folder that is already there and that accounts other than the administrators could write, such as a folder made beforehand at the root of a drive, or when such an installation is upgraded or repaired. 6.3.7 fixed CVE-2026-107571 by giving the program folder, Bin and ControlPanel permissions that only administrators may change, but for a folder that is already there it does so only at the end of setup: setup first copies the programs into Bin, which every user may still write, and runs programs from Bin with the administrator's elevated rights, registering the service among them, before that hardening, so that a library another account places in Bin meanwhile is loaded in place of the system's. A handle an account opened on such a folder while it could write it keeps that access after the hardening. The default installation under Program Files, whose folders give ordinary users read and execute only, is not affected.
Attack profile
How easy it is to exploit
- Attack vector
- Local
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- Required
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
What each source reports
CVE List Score used
7.3
Incorrect Default Permissions in hMailServer
Incorrect default permissions in the Windows installer of Progressive Robot hMailServer 6.3.7 allow a local authenticated user to run code as the administrator who runs setup, when the server is installed into a program folder that is already there and that accounts other than the administrators could write, such as a folder made beforehand at the root of a drive, or when such an installation is upgraded or repaired. 6.3.7 fixed CVE-2026-107571 by giving the program folder, Bin and ControlPanel permissions that only administrators may change, but for a folder that is already there it does so only at the end of setup: setup first copies the programs into Bin, which every user may still write, and runs programs from Bin with the administrator's elevated rights, registering the service among them, before that hardening, so that a library another account places in Bin meanwhile is loaded in place of the system's. A handle an account opened on such a folder while it could write it keeps that access after the hardening. The default installation under Program Files, whose folders give ordinary users read and execute only, is not affected.
- Record
CVE-2026-126622- CVSS 3.1
- 7.3 High
CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H - Weakness
- CWE-276
- Updated
- 2026-11-11
EUVDEUVD-2026-123327
7.3
Incorrect default permissions in the Windows installer of Progressive Robot hMailServer 6.3.7 allow a local authenticated user to run code as the administrator who runs setup, when the server is installed into a program folder that is already there and that accounts other than the administrators could write, such as a folder made beforehand at the root of a drive, or when such an installation is upgraded or repaired. 6.3.7 fixed CVE-2026-107571 by giving the program folder, Bin and ControlPanel permissions that only administrators may change, but for a folder that is already there it does so only at the end of setup: setup first copies the programs into Bin, which every user may still write, and runs programs from Bin with the administrator's elevated rights, registering the service among them, before that hardening, so that a library another account places in Bin meanwhile is loaded in place of the system's. A handle an account opened on such a folder while it could write it keeps that access after the hardening. The default installation under Program Files, whose folders give ordinary users read and execute only, is not affected.
- Record
EUVD-2026-123327- CVSS 3.1
- 7.3 High
CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H - Updated
- 2026-11-11
GitHub AdvisoriesGHSA-45pg-vr27-cp42
7.3
Incorrect default permissions in the Windows installer of Progressive Robot hMailServer 6.3.7...
Incorrect default permissions in the Windows installer of Progressive Robot hMailServer 6.3.7 allow a local authenticated user to run code as the administrator who runs setup, when the server is installed into a program folder that is already there and that accounts other than the administrators could write, such as a folder made beforehand at the root of a drive, or when such an installation is upgraded or repaired. 6.3.7 fixed CVE-2026-107571 by giving the program folder, Bin and ControlPanel permissions that only administrators may change, but for a folder that is already there it does so only at the end of setup: setup first copies the programs into Bin, which every user may still write, and runs programs from Bin with the administrator's elevated rights, registering the service among them, before that hardening, so that a library another account places in Bin meanwhile is loaded in place of the system's. A handle an account opened on such a folder while it could write it keeps that access after the hardening. The default installation under Program Files, whose folders give ordinary users read and execute only, is not affected.
- Record
GHSA-45pg-vr27-cp42- CVSS 3.1
- 7.3 High
CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H - Weakness
- CWE-276
- Updated
- 2026-11-11
NVD
7.3
Incorrect default permissions in the Windows installer of Progressive Robot hMailServer 6.3.7 allow a local authenticated user to run code as the administrator who runs setup, when the server is installed into a program folder that is already there and that accounts other than the administrators could write, such as a folder made beforehand at the root of a drive, or when such an installation is upgraded or repaired. 6.3.7 fixed CVE-2026-107571 by giving the program folder, Bin and ControlPanel permissions that only administrators may change, but for a folder that is already there it does so only at the end of setup: setup first copies the programs into Bin, which every user may still write, and runs programs from Bin with the administrator's elevated rights, registering the service among them, before that hardening, so that a library another account places in Bin meanwhile is loaded in place of the system's. A handle an account opened on such a folder while it could write it keeps that access after the hardening. The default installation under Program Files, whose folders give ordinary users read and execute only, is not affected.
- Record
CVE-2026-126622- CVSS 3.1
- 7.3 High
CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H - Weakness
- CWE-276
- Updated
- 2026-11-11
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| aliases, references | GitHub Advisories | |
| aliases, published | EUVD | |
| first indexed | CVE List |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short