Missing Authentication for Critical Function in Labkotec LID-3300IP

8.8 High

The Labkotec LID-3300IP has an existing vulnerability in the ice detector software that enables an unauthenticated attacker to alter device parameters and run operational commands when specially crafted packets are sent to the device.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
Low
Integrity
High
Availability
High

Exploit likelihood

0.71%Up 0.7 points since Mar 4, 2026
90%50%10%1%

What each source reports

CVE List Score used 8.8

Missing Authentication for Critical Function in Labkotec LID-3300IP

The Labkotec LID-3300IP has an existing vulnerability in the ice detector software that enables an unauthenticated attacker to alter device parameters and run operational commands when specially crafted packets are sent to the device.

Record
CVE-2026-1775
CVSS 4.0
8.8 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N
Weakness
CWE-306
Updated
2026-11-02
EUVDEUVD-2026-9324 8.8

The Labkotec LID-3300IP has an existing vulnerability in the ice detector software that enables an unauthenticated attacker to alter device parameters and run operational commands when specially crafted packets are sent to the device.

Record
EUVD-2026-9324
CVSS 4.0
8.8 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N
Updated
2026-11-02
GitHub AdvisoriesGHSA-v8pw-4mpx-qwjj 8.8

The Labkotec LID-3300IP has an existing vulnerability in the ice detector software that enables...

The Labkotec LID-3300IP has an existing vulnerability in the ice detector software that enables an unauthenticated attacker to alter device parameters and run operational commands when specially crafted packets are sent to the device.

Record
GHSA-v8pw-4mpx-qwjj
CVSS 4.0
8.8 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Weakness
CWE-306
Updated
2026-11-02
NVD 8.8

The Labkotec LID-3300IP has an existing vulnerability in the ice detector software that enables an unauthenticated attacker to alter device parameters and run operational commands when specially crafted packets are sent to the device.

Record
CVE-2026-1775
CVSS 4.0
8.8 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Weakness
CWE-306
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2026-1775 is a high vulnerability (CVSS 8.8) in Labkotec Lid-3300ip, published March 3, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.71%, the 53rd percentile. No source names a fixed version.

References

MoveEnter Open