CVE-2026-18844
Pulsetto Vagus Nerve Stimulator Hidden Functionality
The firmware of the Pulsetto Vagus Nerve Stimulator accepts several undisclosed commands over its Bluetooth Low Energy (BLE) interface. These commands are sent without authentication or encryption, and are never issued by the companion mobile application, yet are fully processed by the device when it is powered on.
Attack profile
How easy it is to exploit
- Attack vector
- Adjacent network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- None
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used
7.2
Pulsetto Vagus Nerve Stimulator Hidden Functionality
The firmware of the Pulsetto Vagus Nerve Stimulator accepts several undisclosed commands over its Bluetooth Low Energy (BLE) interface. These commands are sent without authentication or encryption, and are never issued by the companion mobile application, yet are fully processed by the device when it is powered on.
- Record
CVE-2026-18844- CVSS 4.0
- 7.2 High
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N - CVSS 3.1
- 8.1 High
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H - Weakness
- CWE-912
- Updated
- 2026-11-02
EUVDEUVD-2026-56936
7.2
The firmware of the Pulsetto Vagus Nerve Stimulator accepts several undisclosed commands over its Bluetooth Low Energy (BLE) interface. These commands are sent without authentication or encryption, and are never issued by the companion mobile application, yet are fully processed by the device when it is powered on.
- Record
EUVD-2026-56936- CVSS 4.0
- 7.2 High
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-qhgm-pqrh-9j38
7.2
The firmware of the Pulsetto Vagus Nerve Stimulator accepts several undisclosed commands over its...
The firmware of the Pulsetto Vagus Nerve Stimulator accepts several undisclosed commands over its Bluetooth Low Energy (BLE) interface. These commands are sent without authentication or encryption, and are never issued by the companion mobile application, yet are fully processed by the device when it is powered on.
- Record
GHSA-qhgm-pqrh-9j38- CVSS 4.0
- 7.2 High
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X - CVSS 3.1
- 8.1 High
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H - Weakness
- CWE-912
- Updated
- 2026-11-02
NVD
7.2
The firmware of the Pulsetto Vagus Nerve Stimulator accepts several undisclosed commands over its Bluetooth Low Energy (BLE) interface. These commands are sent without authentication or encryption, and are never issued by the companion mobile application, yet are fully processed by the device when it is powered on.
- Record
CVE-2026-18844- CVSS 4.0
- 7.2 High
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X - CVSS 3.1
- 8.1 High
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H - Weakness
- CWE-912
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2026-18844 is a high vulnerability (CVSS 7.2) in Pulsetto Vagus Nerve Stimulator, published August 11, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.20%, the 10th percentile. No source names a fixed version.