Every CVE Search/ Get API key

CVE-2026-24101

An issue was discovered in goform/formSetIptv in Tenda AC15V1.0 V15.03.05.18_multi. When the...

9.8 Critical

An issue was discovered in goform/formSetIptv in Tenda AC15V1.0 V15.03.05.18_multi. When the condition is met, s1_1 will be passed into sub_B0488, concatenated into doSystemCmd. The value of s1_1 is not validated, potentially leading to a command injection vulnerability.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

1.94%Up 1.7 points since Mar 3, 2026
90%50%10%1%

What each source reports

CVE List Score used 9.8

An issue was discovered in goform/formSetIptv in Tenda AC15V1.0 V15.03.05.18_multi. When the condition is met, s1_1 will be passed into sub_B0488, concatenated into doSystemCmd. The value of s1_1 is not validated, potentially leading to a command injection vulnerability.

Record
CVE-2026-24101
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-78
Updated
2026-11-02
EUVDEUVD-2026-9196 9.8

An issue was discovered in goform/formSetIptv in Tenda AC15V1.0 V15.03.05.18_multi. When the condition is met, s1_1 will be passed into sub_B0488, concatenated into doSystemCmd. The value of s1_1 is not validated, potentially leading to a command injection vulnerability.

Record
EUVD-2026-9196
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Updated
2026-11-02
GitHub AdvisoriesGHSA-mcv3-6wfv-rv64 9.8

An issue was discovered in goform/formSetIptv in Tenda AC15V1.0 V15.03.05.18_multi. When the...

An issue was discovered in goform/formSetIptv in Tenda AC15V1.0 V15.03.05.18_multi. When the condition is met, s1_1 will be passed into sub_B0488, concatenated into doSystemCmd. The value of s1_1 is not validated, potentially leading to a command injection vulnerability.

Record
GHSA-mcv3-6wfv-rv64
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-78
Updated
2026-11-02
NVD 9.8

An issue was discovered in goform/formSetIptv in Tenda AC15V1.0 V15.03.05.18_multi. When the condition is met, s1_1 will be passed into sub_B0488, concatenated into doSystemCmd. The value of s1_1 is not validated, potentially leading to a command injection vulnerability.

Record
CVE-2026-24101
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-78
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2026-24101 is a critical vulnerability (CVSS 9.8) in Tenda Ac15 Firmware, published March 2, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.94%, the 80th percentile. No source names a fixed version.

References

MoveEnter Open