CVE-2026-25599
Missing authentication and clear‑text data transmission affecting Orca heat pumps
Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an unencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an attacker to impersonate a legitimate device and inject malicious payloads. This enables the insertion of harmful code directly into the Orca user portal, potentially compromising user accounts, exposing sensitive information, and allowing further unauthorized actions within the portal.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- Required
What an attacker can affect
- Confidentiality
- Low
- Integrity
- Low
- Availability
- Low
Exploit likelihood
What each source reports
CVE List Score used
6.3
Missing authentication and clear‑text data transmission affecting Orca heat pumps
Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an unencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an attacker to impersonate a legitimate device and inject malicious payloads. This enables the insertion of harmful code directly into the Orca user portal, potentially compromising user accounts, exposing sensitive information, and allowing further unauthorized actions within the portal.
- Record
CVE-2026-25599- CVSS 3.1
- 6.3 Medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L - Weakness
- CWE-79, CWE-306, CWE-319
- Updated
- 2026-11-02
EUVDEUVD-2026-33617
6.3
Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an unencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an attacker to impersonate a legitimate device and inject malicious payloads. This enables the insertion of harmful code directly into the Orca user portal, potentially compromising user accounts, exposing sensitive information, and allowing further unauthorized actions within the portal.
- Record
EUVD-2026-33617- CVSS 3.1
- 6.3 Medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-m272-v6vr-r4ff
6.3
Missing authentication and clear‑text transmission of data from the heat pumps to the control...
Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an unencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an attacker to impersonate a legitimate device and inject malicious payloads. This enables the insertion of harmful code directly into the Orca user portal, potentially compromising user accounts, exposing sensitive information, and allowing further unauthorized actions within the portal.
- Record
GHSA-m272-v6vr-r4ff- CVSS 3.1
- 6.3 Medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L - Weakness
- CWE-79
- Updated
- 2026-11-02
NVD
6.3
Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an unencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an attacker to impersonate a legitimate device and inject malicious payloads. This enables the insertion of harmful code directly into the Orca user portal, potentially compromising user accounts, exposing sensitive information, and allowing further unauthorized actions within the portal.
- Record
CVE-2026-25599- CVSS 3.1
- 6.3 Medium
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L - Weakness
- CWE-79, CWE-306, CWE-319
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2026-25599 is a medium vulnerability (CVSS 6.3) in Orca Energy Heat Pump, published June 1, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.11%, the 1st percentile. No source names a fixed version.