CVE-2026-35065
Dell PowerFlex Manager, version(s) [Versions], contain(s) a Missing Authentication for Critical...
Dell PowerFlex Manager, version(s) prior to 5.1.0.1, contain(s) a Missing Authentication for Critical Function vulnerability. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Code execution, Denial of service, Information disclosure, Information tampering, Remote execution, Script injection, and Unauthorized access.
Attack profile
How easy it is to exploit
- Attack vector
- Adjacent network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used
8.8
Dell PowerFlex Manager, version(s) prior to 5.1.0.1, contain(s) a Missing Authentication for Critical Function vulnerability. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Code execution, Denial of service, Information disclosure, Information tampering, Remote execution, Script injection, and Unauthorized access.
- Record
CVE-2026-35065- CVSS 3.1
- 8.8 High
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-306
- Updated
- 2026-11-02
EUVDEUVD-2026-37733
8.8
Dell PowerFlex Manager, version(s) prior to 5.1.0.1, contain(s) a Missing Authentication for Critical Function vulnerability. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Code execution, Denial of service, Information disclosure, Information tampering, Remote execution, Script injection, and Unauthorized access.
- Record
EUVD-2026-37733- CVSS 3.1
- 8.8 High
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-wfcw-3pw3-83c9
8.8
Dell PowerFlex Manager, version(s) [Versions], contain(s) a Missing Authentication for Critical...
Dell PowerFlex Manager, version(s) [Versions], contain(s) a Missing Authentication for Critical Function vulnerability. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Code execution, Denial of service, Information disclosure, Information tampering, Remote execution, Script injection, and Unauthorized access.
- Record
GHSA-wfcw-3pw3-83c9- CVSS 3.1
- 8.8 High
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-306
- Updated
- 2026-11-02
NVD
8.8
Dell PowerFlex Manager, version(s) prior to 5.1.0.1, contain(s) a Missing Authentication for Critical Function vulnerability. An unauthenticated attacker with adjacent network access could potentially exploit this vulnerability, leading to Code execution, Denial of service, Information disclosure, Information tampering, Remote execution, Script injection, and Unauthorized access.
- Record
CVE-2026-35065- CVSS 3.1
- 8.8 High
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-306
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2026-35065 is a high vulnerability (CVSS 8.8) in Dell Powerflex, published June 17, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.35%, the 29th percentile. No source names a fixed version.