CVE-2026-35070
Dell SmartFabric Storage Software, versions prior to 1.4.5, contains an Improper Neutralization...
Dell SmartFabric Storage Software, versions prior to 1.4.5, contains an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker.
Attack profile
How easy it is to exploit
- Attack vector
- Local
- Complexity
- High
- Privileges needed
- High
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used
6.4
Dell SmartFabric Storage Software, versions prior to 1.4.5, contains an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker.
- Record
CVE-2026-35070- CVSS 3.1
- 6.4 Medium
CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-77
- Updated
- 2026-11-02
EUVDEUVD-2026-31086
6.4
Dell SmartFabric Storage Software, versions prior to 1.4.5, contains an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker.
- Record
EUVD-2026-31086- CVSS 3.1
- 6.4 Medium
CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-7rmc-4wcf-hgwm
6.4
Dell SmartFabric Storage Software, versions prior to 1.4.5, contains an Improper Neutralization...
Dell SmartFabric Storage Software, versions prior to 1.4.5, contains an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker.
- Record
GHSA-7rmc-4wcf-hgwm- CVSS 3.1
- 6.4 Medium
CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-77
- Updated
- 2026-11-02
NVD
6.4
Dell SmartFabric Storage Software, versions prior to 1.4.5, contains an Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Filesystem access for attacker.
- Record
CVE-2026-35070- CVSS 3.1
- 6.4 Medium
CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H - CVSS 3.1
- 6.7 Medium
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-77
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short