CVE-2026-3560
Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability
Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the hk_hap_pair_storage_put function of the HomeKit implementation, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28469.
Attack profile
How easy it is to exploit
- Attack vector
- Adjacent network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used
8.8
Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability
Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the hk_hap_pair_storage_put function of the HomeKit implementation, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28469.
- Record
CVE-2026-3560- CVSS 3.0
- 8.8 High
CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-122
- Updated
- 2026-11-02
EUVDEUVD-2026-12161
8.8
Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the hk_hap_pair_storage_put function of the HomeKit implementation, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28469.
- Record
EUVD-2026-12161- CVSS 3.0
- 8.8 High
CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-7wwf-329w-9wr3
8.8
Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code...
Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the hk_hap_pair_storage_put function of the HomeKit implementation, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28469.
- Record
GHSA-7wwf-329w-9wr3- CVSS 3.0
- 8.8 High
CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-122
- Updated
- 2026-11-02
NVD
8.8
Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the hk_hap_pair_storage_put function of the HomeKit implementation, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28469.
- Record
CVE-2026-3560- CVSS 3.0
- 8.8 High
CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-122
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2026-3560 is a high vulnerability (CVSS 8.8) in Philips Hue Bridge, published March 13, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.58%, the 48th percentile. No source names a fixed version.