CVE-2026-36777
Shenzhen Tenda Technology Co., Ltd Tenda W3 Wireless Router v1.0.0.3(2204) was discovered to...
Shenzhen Tenda Technology Co., Ltd Tenda W3 Wireless Router v1.0.0.3(2204) was discovered to contain a stack overflow in the param_1 parameter of the formSetCfm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted HTTP request.
Attack profile
How easy it is to exploit
- Attack vector
- Adjacent network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- None
- Integrity
- None
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used
6.5
Shenzhen Tenda Technology Co., Ltd Tenda W3 Wireless Router v1.0.0.3(2204) was discovered to contain a stack overflow in the param_1 parameter of the formSetCfm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted HTTP request.
- Record
CVE-2026-36777- CVSS 3.1
- 6.5 Medium
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - Weakness
- CWE-121
- Updated
- 2026-11-02
EUVDEUVD-2026-35935
6.5
Shenzhen Tenda Technology Co., Ltd Tenda W3 Wireless Router v1.0.0.3(2204) was discovered to contain a stack overflow in the param_1 parameter of the formSetCfm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted HTTP request.
- Record
EUVD-2026-35935- CVSS 3.1
- 6.5 Medium
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-cp2j-fxf4-h2xw
6.5
Shenzhen Tenda Technology Co., Ltd Tenda W3 Wireless Router v1.0.0.3(2204) was discovered to...
Shenzhen Tenda Technology Co., Ltd Tenda W3 Wireless Router v1.0.0.3(2204) was discovered to contain a stack overflow in the param_1 parameter of the formSetCfm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted HTTP request.
- Record
GHSA-cp2j-fxf4-h2xw- CVSS 3.1
- 6.5 Medium
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - Weakness
- CWE-121
- Updated
- 2026-11-02
NVD
6.5
Shenzhen Tenda Technology Co., Ltd Tenda W3 Wireless Router v1.0.0.3(2204) was discovered to contain a stack overflow in the param_1 parameter of the formSetCfm function. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted HTTP request.
- Record
CVE-2026-36777- CVSS 3.1
- 6.5 Medium
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - Weakness
- CWE-121
- Updated
- 2026-11-02
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2026-36777 is a medium vulnerability (CVSS 6.5), published June 9, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.22%, the 12th percentile. No source names a fixed version.