Every CVE Search/ Get API key

CVE-2026-5397

Vulnerability Related to an Uncontrolled Search Path Element in a UPS Management Application

7.8 High

It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that is then executed with administrator privileges.

If a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL may be executed by exploiting the product’s behavior of loading missing DLLs from the same directory as the executable during service startup.

Attack profile

How easy it is to exploit

Attack vector
Local
Complexity
High
Privileges needed
Low
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

0.13%Up 0.1 points since Apr 15, 2026
90%50%10%1%

What each source reports

CVE List Score used 7.8

Vulnerability Related to an Uncontrolled Search Path Element in a UPS Management Application

It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that is then executed with administrator privileges.

If a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL may be executed by exploiting the product’s behavior of loading missing DLLs from the same directory as the executable during service startup.

Record
CVE-2026-5397
CVSS 3.1
7.8 HighCVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H
Weakness
CWE-427
Updated
2026-11-02
EUVDEUVD-2026-22837 7.8

It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that is then executed with administrator privileges.

If a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL may be executed by exploiting the product’s behavior of loading missing DLLs from the same directory as the executable during service startup.

Record
EUVD-2026-22837
CVSS 3.1
7.8 HighCVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H
Updated
2026-11-02
GitHub AdvisoriesGHSA-wx9r-9hf2-wq9p 7.8

It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power...

It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that is then executed with administrator privileges.

If a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL may be executed by exploiting the product’s behavior of loading missing DLLs from the same directory as the executable during service startup.

Record
GHSA-wx9r-9hf2-wq9p
CVSS 3.1
7.8 HighCVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H
Weakness
CWE-427
Updated
2026-11-02
NVD 7.8

It has been identified that a vulnerability (CWE-427) exists in the UPS (Uninterruptible Power Supply) management application, whereby improper permissions on the installation directory allow a malicious actor to place a DLL that is then executed with administrator privileges.

If a malicious DLL is placed in the installation directory of this product, there is a possibility that the malicious DLL may be executed by exploiting the product’s behavior of loading missing DLLs from the same directory as the executable during service startup.

Record
CVE-2026-5397
CVSS 3.1
7.8 HighCVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H
Weakness
CWE-427
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2026-5397 is a high vulnerability (CVSS 7.8) in Omron Social Solutions Co., Ltd. Powerattendant Standard Edition, published April 15, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.13%, the 2nd percentile. No source names a fixed version.

References

MoveEnter Open