CVE-2026-5777
Security Misconfiguration Vulnerability in Atom 3x Projector
This vulnerability exists in the Atom 3x Projector due to improper exposure of the Android Debug Bridge (ADB) service over the local network without authentication or access controls. An unauthenticated attacker on the same network can exploit this vulnerability to obtain root-level access, leading to complete compromise of the targeted device.
Attack profile
How easy it is to exploit
- Attack vector
- Adjacent network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used
8.7
Security Misconfiguration Vulnerability in Atom 3x Projector
This vulnerability exists in the Atom 3x Projector due to improper exposure of the Android Debug Bridge (ADB) service over the local network without authentication or access controls. An unauthenticated attacker on the same network can exploit this vulnerability to obtain root-level access, leading to complete compromise of the targeted device.
- Record
CVE-2026-5777- CVSS 4.0
- 8.7 High
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N - Weakness
- CWE-306
- Updated
- 2026-11-02
EUVDEUVD-2026-21368
8.7
This vulnerability exists in the Atom 3x Projector due to improper exposure of the Android Debug Bridge (ADB) service over the local network without authentication or access controls. An unauthenticated attacker on the same network can exploit this vulnerability to obtain root-level access, leading to complete compromise of the targeted device.
- Record
EUVD-2026-21368- CVSS 4.0
- 8.7 High
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-3jqw-2342-vgxw
8.7
This vulnerability exists in the Atom 3x Projector due to improper exposure of the Android Debug...
This vulnerability exists in the Atom 3x Projector due to improper exposure of the Android Debug Bridge (ADB) service over the local network without authentication or access controls. An unauthenticated attacker on the same network can exploit this vulnerability to obtain root-level access, leading to complete compromise of the targeted device.
- Record
GHSA-3jqw-2342-vgxw- CVSS 4.0
- 8.7 High
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X - Weakness
- CWE-306
- Updated
- 2026-11-02
NVD
8.7
This vulnerability exists in the Atom 3x Projector due to improper exposure of the Android Debug Bridge (ADB) service over the local network without authentication or access controls. An unauthenticated attacker on the same network can exploit this vulnerability to obtain root-level access, leading to complete compromise of the targeted device.
- Record
CVE-2026-5777- CVSS 4.0
- 8.7 High
CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X - Weakness
- CWE-306
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2026-5777 is a high vulnerability (CVSS 8.7) in Egate Atom 3x Projector, published April 10, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.33%, the 26th percentile. No source names a fixed version.