Every CVE Search/ Get API key

CVE-2026-71921

DrayTek VigorSwitch Multiple Models Pre-Authentication OS Command Injection via setget.cgi

9.3 Critical

Multiple DrayTek VigorSwitch models contain a pre-authentication command injection vulnerability in the setget.cgi interface. The vulnerability is caused by insufficient filtering of the pass field before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

2.79%Down 0.5 points since Aug 25, 2026
90%50%10%1%

What each source reports

CVE List Score used 9.3

DrayTek VigorSwitch Multiple Models Pre-Authentication OS Command Injection via setget.cgi

Multiple DrayTek VigorSwitch models contain a pre-authentication command injection vulnerability in the setget.cgi interface. The vulnerability is caused by insufficient filtering of the pass field before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges.

Record
CVE-2026-71921
CVSS 4.0
9.3 CriticalCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-78
Updated
2026-11-02
EUVDEUVD-2026-64980 9.3

Multiple DrayTek VigorSwitch models contain a pre-authentication command injection vulnerability in the setget.cgi interface. The vulnerability is caused by insufficient filtering of the pass field before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges.

Record
EUVD-2026-64980
CVSS 4.0
9.3 CriticalCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N
Updated
2026-11-02
GitHub AdvisoriesGHSA-c34j-h938-5r57 9.3

Multiple DrayTek VigorSwitch models contain a pre-authentication command injection vulnerability...

Multiple DrayTek VigorSwitch models contain a pre-authentication command injection vulnerability in the setget.cgi interface. The vulnerability is caused by insufficient filtering of the pass field before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges.

Record
GHSA-c34j-h938-5r57
CVSS 4.0
9.3 CriticalCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-78
Updated
2026-11-02
NVD 9.3

Multiple DrayTek VigorSwitch models contain a pre-authentication command injection vulnerability in the setget.cgi interface. The vulnerability is caused by insufficient filtering of the pass field before command execution. A remote attacker can trigger this vulnerability via crafted input to execute arbitrary commands with root privileges.

Record
CVE-2026-71921
CVSS 4.0
9.3 CriticalCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-78
Updated
2026-11-02

Affected products

Show 16 moreShow less

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2026-71921 is a critical vulnerability (CVSS 9.3) in Draytek Corporation Vigorswitch Fx2120, published August 24, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 2.79%, the 86th percentile. No source names a fixed version.

References