Every CVE Search/ Get API key

CVE-2026-7470

Tenda 4G300 SafeMacFilter sub_427C3C stack-based overflow

8.7 High

A flaw has been found in Tenda 4G300 US_4G300V1.0Mt_V1.01.42_CN_TDC01. Affected is the function sub_427C3C of the file /goform/SafeMacFilter. This manipulation of the argument page causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
Low
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

0.52%Up 0.5 points since Apr 30, 2026
90%50%10%1%

What each source reports

CVE List Score used 8.7

Tenda 4G300 SafeMacFilter sub_427C3C stack-based overflow

A flaw has been found in Tenda 4G300 US_4G300V1.0Mt_V1.01.42_CN_TDC01. Affected is the function sub_427C3C of the file /goform/SafeMacFilter. This manipulation of the argument page causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used.

Record
CVE-2026-7470
CVSS 4.0
8.7 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
CVSS 3.1
8.8 HighCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
CVSS 3.0
8.8 HighCVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R
CVSS 2.0
9.0 AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR
Weakness
CWE-121, CWE-119
Updated
2026-11-02
EUVDEUVD-2026-26307 8.7

A flaw has been found in Tenda 4G300 US_4G300V1.0Mt_V1.01.42_CN_TDC01. Affected is the function sub_427C3C of the file /goform/SafeMacFilter. This manipulation of the argument page causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used.

Record
EUVD-2026-26307
CVSS 4.0
8.7 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P
Updated
2026-11-02
GitHub AdvisoriesGHSA-jc4x-cmh7-8379 7.4

A flaw has been found in Tenda 4G300 US_4G300V1.0Mt_V1.01.42_CN_TDC01. Affected is the function...

A flaw has been found in Tenda 4G300 US_4G300V1.0Mt_V1.01.42_CN_TDC01. Affected is the function sub_427C3C of the file /goform/SafeMacFilter. This manipulation of the argument page causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used.

Record
GHSA-jc4x-cmh7-8379
CVSS 4.0
7.4 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
8.8 HighCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-119
Updated
2026-11-02
NVD 7.4

A flaw has been found in Tenda 4G300 US_4G300V1.0Mt_V1.01.42_CN_TDC01. Affected is the function sub_427C3C of the file /goform/SafeMacFilter. This manipulation of the argument page causes stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been published and may be used.

Record
CVE-2026-7470
CVSS 4.0
7.4 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
8.8 HighCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
9.0 HighAV:N/AC:L/Au:S/C:C/I:C/A:C
Weakness
CWE-119, CWE-121
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2026-7470 is a high vulnerability (CVSS 8.7) in Tenda 4g300, published April 30, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.52%, the 44th percentile. No source names a fixed version.

References

MoveEnter Open