Every CVE Search/ Get API key

CVE-2026-76262

Exposure of Sensitive Information to an Unauthorized Actor through the REST API in Splunk Enterprise

7.5 High

In Splunk Enterprise 10.4 versions below 10.4.2, an unauthenticated user could read Prometheus service metrics from the Edge Processor SPL2 Preview sidecar, including service details that expose relevant runtime and build metadata for the sidecar. The vulnerability does not affect Splunk Enterprise versions below 10.4. The information disclosure is possible because the Prometheus metrics endpoint in the Edge Processor SPL2 Preview sidecar lacks authentication, which lets any client that can reach the sidecar retrieve the metrics without credentials. For more information see About Splunk sidecars (https://help.splunk.com/en/splunk-enterprise/administer/admin-manual/10.4/splunk-sidecars/about-splunk-sidecars) in the Splunk documentation.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
None
Availability
None

Exploit likelihood

0.50%Up 0.1 points since Aug 20, 2026
90%50%10%1%

What each source reports

CVE List Score used 7.5

Exposure of Sensitive Information to an Unauthorized Actor through the REST API in Splunk Enterprise

In Splunk Enterprise 10.4 versions below 10.4.2, an unauthenticated user could read Prometheus service metrics from the Edge Processor SPL2 Preview sidecar, including service details that expose relevant runtime and build metadata for the sidecar. The vulnerability does not affect Splunk Enterprise versions below 10.4. The information disclosure is possible because the Prometheus metrics endpoint in the Edge Processor SPL2 Preview sidecar lacks authentication, which lets any client that can reach the sidecar retrieve the metrics without credentials. For more information see About Splunk sidecars (https://help.splunk.com/en/splunk-enterprise/administer/admin-manual/10.4/splunk-sidecars/about-splunk-sidecars) in the Splunk documentation.

Record
CVE-2026-76262
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Weakness
CWE-200
Updated
2026-11-02
EUVDEUVD-2026-63114 7.5

In Splunk Enterprise 10.4 versions below 10.4.2, an unauthenticated user could read Prometheus service metrics from the Edge Processor SPL2 Preview sidecar, including service details that expose relevant runtime and build metadata for the sidecar. The vulnerability does not affect Splunk Enterprise versions below 10.4. The information disclosure is possible because the Prometheus metrics endpoint in the Edge Processor SPL2 Preview sidecar lacks authentication, which lets any client that can reach the sidecar retrieve the metrics without credentials. For more information see About Splunk sidecars (https://help.splunk.com/en/splunk-enterprise/administer/admin-manual/10.4/splunk-sidecars/about-splunk-sidecars) in the Splunk documentation.

Record
EUVD-2026-63114
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Updated
2026-11-02
GitHub AdvisoriesGHSA-9m2v-75c6-7v47 7.5

In Splunk Enterprise 10.4 versions below 10.4.2, an unauthenticated user could read Prometheus...

In Splunk Enterprise 10.4 versions below 10.4.2, an unauthenticated user could read Prometheus service metrics from the Edge Processor SPL2 Preview sidecar, including service details that expose relevant runtime and build metadata for the sidecar. The vulnerability does not affect Splunk Enterprise versions below 10.4. The information disclosure is possible because the Prometheus metrics endpoint in the Edge Processor SPL2 Preview sidecar lacks authentication, which lets any client that can reach the sidecar retrieve the metrics without credentials. For more information see About Splunk sidecars (https://help.splunk.com/en/splunk-enterprise/administer/admin-manual/10.4/splunk-sidecars/about-splunk-sidecars) in the Splunk documentation.

Record
GHSA-9m2v-75c6-7v47
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Weakness
CWE-200
Updated
2026-11-02
NVD 7.5

In Splunk Enterprise 10.4 versions below 10.4.2, an unauthenticated user could read Prometheus service metrics from the Edge Processor SPL2 Preview sidecar, including service details that expose relevant runtime and build metadata for the sidecar. The vulnerability does not affect Splunk Enterprise versions below 10.4. The information disclosure is possible because the Prometheus metrics endpoint in the Edge Processor SPL2 Preview sidecar lacks authentication, which lets any client that can reach the sidecar retrieve the metrics without credentials. For more information see About Splunk sidecars (https://help.splunk.com/en/splunk-enterprise/administer/admin-manual/10.4/splunk-sidecars/about-splunk-sidecars) in the Splunk documentation.

Record
CVE-2026-76262
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Weakness
CWE-200
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2026-76262 is a high vulnerability (CVSS 7.5) in Splunk, published August 19, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.50%, the 43rd percentile. No source names a fixed version.