Every CVE Search/ Get API key

CVE-2026-77549

A malicious actor with access to the network and under certain conditions could exploit an...

9.0 Critical

A malicious actor with access to the network and under certain conditions could exploit an Improper Neutralization of CRLF Sequences vulnerability found in certain devices running UniFi OS to bypass authentication to such UniFi OS devices or instances.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
High
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

0.51%Up 0.2 points since Aug 27, 2026
90%50%10%1%

What each source reports

CVE List Score used 9.0

A malicious actor with access to the network and under certain conditions could exploit an Improper Neutralization of CRLF Sequences vulnerability found in certain devices running UniFi OS to bypass authentication to such UniFi OS devices or instances.

Record
CVE-2026-77549
CVSS 3.1
9.0 CriticalCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
Weakness
CWE-93
Updated
2026-11-02
EUVDEUVD-2026-66398 9.0

A malicious actor with access to the network and under certain conditions could exploit an Improper Neutralization of CRLF Sequences vulnerability found in certain devices running UniFi OS to bypass authentication to such UniFi OS devices or instances.

Record
EUVD-2026-66398
CVSS 3.1
9.0 CriticalCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
Updated
2026-11-02
GitHub AdvisoriesGHSA-g4h7-m732-3278 9.0

A malicious actor with access to the network and under certain conditions could exploit an...

A malicious actor with access to the network and under certain conditions could exploit an Improper Neutralization of CRLF Sequences vulnerability found in certain devices running UniFi OS to bypass authentication to such UniFi OS devices or instances.

Record
GHSA-g4h7-m732-3278
CVSS 3.1
9.0 CriticalCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
Weakness
CWE-93
Updated
2026-11-02
NVD 9.0

A malicious actor with access to the network and under certain conditions could exploit an Improper Neutralization of CRLF Sequences vulnerability found in certain devices running UniFi OS to bypass authentication to such UniFi OS devices or instances.

Record
CVE-2026-77549
CVSS 3.1
9.0 CriticalCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
Weakness
CWE-93
Updated
2026-11-02

Affected products

Show 3 moreShow less

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2026-77549 is a critical vulnerability (CVSS 9.0) in @clerk Express, published August 26, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.51%, the 43rd percentile. No source names a fixed version.

References

MoveEnter Open