CVE-2026-79316
An improper access control vulnerability exists in x-ui 0.3.2. Any authenticated panel user can...
An improper access control vulnerability exists in x-ui 0.3.2. Any authenticated panel user can modify the xray configuration template through the settings interface and trigger a panel restart, causing the xray management gRPC service, which is bound to loopback by default, to be regenerated and bound to non-loopback addresses. This expands the reachable surface of the management interface beyond its intended local-only boundary.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- Low
- Availability
- Low
Exploit likelihood
What each source reports
CVE List Score used 7.6
An improper access control vulnerability exists in x-ui 0.3.2. Any authenticated panel user can modify the xray configuration template through the settings interface and trigger a panel restart, causing the xray management gRPC service, which is bound to loopback by default, to be regenerated and bound to non-loopback addresses. This expands the reachable surface of the management interface beyond its intended local-only boundary.
- Record
CVE-2026-79316- CVSS 3.1
- 7.6 High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L - Weakness
- CWE-284
- Updated
- 2026-11-02
EUVDEUVD-2026-84205 7.6
An improper access control vulnerability exists in x-ui 0.3.2. Any authenticated panel user can modify the xray configuration template through the settings interface and trigger a panel restart, causing the xray management gRPC service, which is bound to loopback by default, to be regenerated and bound to non-loopback addresses. This expands the reachable surface of the management interface beyond its intended local-only boundary.
- Record
EUVD-2026-84205- CVSS 3.1
- 7.6 High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-x7jv-2m23-2ch3 7.6
An improper access control vulnerability exists in x-ui 0.3.2. Any authenticated panel user can...
An improper access control vulnerability exists in x-ui 0.3.2. Any authenticated panel user can modify the xray configuration template through the settings interface and trigger a panel restart, causing the xray management gRPC service, which is bound to loopback by default, to be regenerated and bound to non-loopback addresses. This expands the reachable surface of the management interface beyond its intended local-only boundary.
- Record
GHSA-x7jv-2m23-2ch3- CVSS 3.1
- 7.6 High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L - Weakness
- CWE-284
- Updated
- 2026-11-02
NVD 7.6
An improper access control vulnerability exists in x-ui 0.3.2. Any authenticated panel user can modify the xray configuration template through the settings interface and trigger a panel restart, causing the xray management gRPC service, which is bound to loopback by default, to be regenerated and bound to non-loopback addresses. This expands the reachable surface of the management interface beyond its intended local-only boundary.
- Record
CVE-2026-79316- CVSS 3.1
- 7.6 High
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:L - Weakness
- CWE-284
- Updated
- 2026-11-02
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2026-79316 is a high vulnerability (CVSS 7.6), published September 21, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.32%, the 25th percentile. No source names a fixed version.