Every CVESearch/Get API key

CVE-2026-79641

Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior...

7.5 High

Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to elevation of privileges.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
High
Privileges needed
Low
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

1.13%Up 0.5 points since Sep 10, 2026
90%50%10%1%

What each source reports

CVE List Score used7.5

Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to elevation of privileges.

Record
CVE-2026-79641
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-78
Updated
2026-11-02
EUVDEUVD-2026-747987.5

Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to elevation of privileges.

Record
EUVD-2026-74798
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H
Updated
2026-11-02
GitHub AdvisoriesGHSA-xxcf-rj2c-3wrj7.5

Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior...

Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to elevation of privileges.

Record
GHSA-xxcf-rj2c-3wrj
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-78
Updated
2026-11-02
NVD7.5

Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to elevation of privileges.

Record
CVE-2026-79641
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-78
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2026-79641 is a high vulnerability (CVSS 7.5) in Dell Secure Connect Gateway 5.0 - Appliance, published September 9, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.13%, the 66th percentile. No source names a fixed version.