CVE-2026-80172
Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior...
Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Insufficient Verification of Data Authenticity vulnerability. An unauthenticated attacker with remote access could exploit this, leading to unauthorized access. This vulnerability is considered critical as an unauthenticated attacker can repeatedly reuse a captured request to generate ADMIN access and refresh tokens. Since there is no nonce validation or time limit on requests, the attack can be performed indefinitely. Dell recommends customers to upgrade at the earliest opportunity
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
What each source reports
CVE List Score used 9.8
Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Insufficient Verification of Data Authenticity vulnerability. An unauthenticated attacker with remote access could exploit this, leading to unauthorized access. This vulnerability is considered critical as an unauthenticated attacker can repeatedly reuse a captured request to generate ADMIN access and refresh tokens. Since there is no nonce validation or time limit on requests, the attack can be performed indefinitely. Dell recommends customers to upgrade at the earliest opportunity
- Record
CVE-2026-80172- CVSS 3.1
- 9.8 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-345
- Updated
- 2026-11-02
EUVDEUVD-2026-74853 9.8
Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Insufficient Verification of Data Authenticity vulnerability. An unauthenticated attacker with remote access could exploit this, leading to unauthorized access. This vulnerability is considered critical as an unauthenticated attacker can repeatedly reuse a captured request to generate ADMIN access and refresh tokens. Since there is no nonce validation or time limit on requests, the attack can be performed indefinitely. Dell recommends customers to upgrade at the earliest opportunity
- Record
EUVD-2026-74853- CVSS 3.1
- 9.8 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-f8g2-6jhm-qr64 9.8
Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior...
Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Insufficient Verification of Data Authenticity vulnerability. An unauthenticated attacker with remote access could exploit this, leading to unauthorized access. This vulnerability is considered critical as an unauthenticated attacker can repeatedly reuse a captured request to generate ADMIN access and refresh tokens. Since there is no nonce validation or time limit on requests, the attack can be performed indefinitely. Dell recommends customers to upgrade at the earliest opportunity
- Record
GHSA-f8g2-6jhm-qr64- CVSS 3.1
- 9.8 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-345
- Updated
- 2026-11-02
NVD 9.8
Dell SCG 5.0 Appliance versions prior to 5.36.00.16 and Dell SCG 5.0 Application versions prior to 5.36.00.00, contains an Insufficient Verification of Data Authenticity vulnerability. An unauthenticated attacker with remote access could exploit this, leading to unauthorized access. This vulnerability is considered critical as an unauthenticated attacker can repeatedly reuse a captured request to generate ADMIN access and refresh tokens. Since there is no nonce validation or time limit on requests, the attack can be performed indefinitely. Dell recommends customers to upgrade at the earliest opportunity
- Record
CVE-2026-80172- CVSS 3.1
- 9.8 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-345
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2026-80172 is a critical vulnerability (CVSS 9.8) in Dell Secure Connect Gateway 5.0 - Appliance, published September 9, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.25%, the 17th percentile. No source names a fixed version.