CVE-2026-80276
Comelit 1456B gateway exposes remote configuration password via unauthenticated management interface
Comelit Multi-User Gateway for VIP System (model 1456B) firmware versions 2.9.1 and 2.10.0 expose a network-accessible management interface that does not require authentication. Through this interface, sensitive device configuration data - including the Remote Configuration Password - can be read in cleartext by a remote, unauthenticated attacker.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- None
- Availability
- None
Exploit likelihood
What each source reports
CVE List Score used
7.5
Comelit 1456B gateway exposes remote configuration password via unauthenticated management interface
Comelit Multi-User Gateway for VIP System (model 1456B) firmware versions 2.9.1 and 2.10.0 expose a network-accessible management interface that does not require authentication. Through this interface, sensitive device configuration data - including the Remote Configuration Password - can be read in cleartext by a remote, unauthenticated attacker.
- Record
CVE-2026-80276- CVSS 3.1
- 7.5 High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N - Weakness
- CWE-306
- Updated
- 2026-11-02
EUVDEUVD-2026-90503
7.5
Comelit Multi-User Gateway for VIP System (model 1456B) firmware versions 2.9.1 and 2.10.0 expose a network-accessible management interface that does not require authentication. Through this interface, sensitive device configuration data - including the Remote Configuration Password - can be read in cleartext by a remote, unauthenticated attacker.
- Record
EUVD-2026-90503- CVSS 3.1
- 7.5 High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N - Updated
- 2026-11-02
GitHub AdvisoriesGHSA-g5xq-fc7g-hgv3
7.5
Comelit Multi-User Gateway for VIP System (model 1456B) firmware versions 2.9.1 and 2.10.0 expose...
Comelit Multi-User Gateway for VIP System (model 1456B) firmware versions 2.9.1 and 2.10.0 expose a network-accessible management interface that does not require authentication. Through this interface, sensitive device configuration data - including the Remote Configuration Password - can be read in cleartext by a remote, unauthenticated attacker.
- Record
GHSA-g5xq-fc7g-hgv3- CVSS 3.1
- 7.5 High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N - Weakness
- CWE-306
- Updated
- 2026-11-02
NVD
7.5
Comelit Multi-User Gateway for VIP System (model 1456B) firmware versions 2.9.1 and 2.10.0 expose a network-accessible management interface that does not require authentication. Through this interface, sensitive device configuration data - including the Remote Configuration Password - can be read in cleartext by a remote, unauthenticated attacker.
- Record
CVE-2026-80276- CVSS 3.1
- 7.5 High
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N - Weakness
- CWE-306
- Updated
- 2026-11-02
Affected products
History
| Recorded | Changed | Sources |
|---|---|---|
| first indexed | CVE List, EUVD, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.
In short
CVE-2026-80276 is a high vulnerability (CVSS 7.5) in Comelit Group S.p.a. 1456b Multi-user Gateway, published October 1, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.37%, the 30th percentile. No source names a fixed version.