Every CVE Search/ Get API key

CVE-2026-8033

PicoTronica e-Clinic Healthcare System ECHS Response Header v2 information disclosure

6.9 Medium

A vulnerability has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. This affects an unknown function of the file /cdemos/echs/api/v2/ of the component Response Header Handler. Such manipulation leads to information disclosure. The attack may be performed from remote. The exploit has been disclosed to the public and may be used. Upgrading to version 5.7.1 mitigates this issue. It is suggested to upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
Low
Integrity
None
Availability
None

Exploit likelihood

0.29%Up 0.3 points since May 7, 2026
90%50%10%1%

What each source reports

CVE List Score used 6.9

PicoTronica e-Clinic Healthcare System ECHS Response Header v2 information disclosure

A vulnerability has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. This affects an unknown function of the file /cdemos/echs/api/v2/ of the component Response Header Handler. Such manipulation leads to information disclosure. The attack may be performed from remote. The exploit has been disclosed to the public and may be used. Upgrading to version 5.7.1 mitigates this issue. It is suggested to upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.

Record
CVE-2026-8033
CVSS 4.0
6.9 MediumCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P
CVSS 3.1
5.3 MediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C
CVSS 3.0
5.3 MediumCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C
CVSS 2.0
5.0 AV:N/AC:L/Au:N/C:P/I:N/A:N/E:POC/RL:OF/RC:C
Weakness
CWE-200, CWE-284
Updated
2026-11-02
EUVDEUVD-2026-28206 6.9

A vulnerability has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. This affects an unknown function of the file /cdemos/echs/api/v2/ of the component Response Header Handler. Such manipulation leads to information disclosure. The attack may be performed from remote. The exploit has been disclosed to the public and may be used. Upgrading to version 5.7.1 mitigates this issue. It is suggested to upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.

Record
EUVD-2026-28206
CVSS 4.0
6.9 MediumCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P
Updated
2026-11-02
GitHub AdvisoriesGHSA-fr47-rhr6-cfq2 5.5

A vulnerability has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. This affects...

A vulnerability has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. This affects an unknown function of the file /cdemos/echs/api/v2/ of the component Response Header Handler. Such manipulation leads to information disclosure. The attack may be performed from remote. The exploit has been disclosed to the public and may be used. Upgrading to version 5.7.1 mitigates this issue. It is suggested to upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.

Record
GHSA-fr47-rhr6-cfq2
CVSS 4.0
5.5 MediumCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
5.3 MediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Weakness
CWE-200
Updated
2026-11-02
NVD 5.5

A vulnerability has been found in PicoTronica e-Clinic Healthcare System ECHS 5.7. This affects an unknown function of the file /cdemos/echs/api/v2/ of the component Response Header Handler. Such manipulation leads to information disclosure. The attack may be performed from remote. The exploit has been disclosed to the public and may be used. Upgrading to version 5.7.1 mitigates this issue. It is suggested to upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.

Record
CVE-2026-8033
CVSS 4.0
5.5 MediumCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
5.3 MediumCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
CVSS 2.0
5.0 MediumAV:N/AC:L/Au:N/C:P/I:N/A:N
Weakness
CWE-200, CWE-284
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2026-8033 is a medium vulnerability (CVSS 6.9) in Picotronica E-clinic Healthcare System Echs, published May 6, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.29%, the 21st percentile. No source names a fixed version.

References

MoveEnter Open