Every CVE Search/ Get API key

CVE-2026-81490

MongoDB Connector for BI Improper Error Handling During Schema Sampling May Cause Loss of SQL Service

8.3 High

A database user able to create a view in a namespace that MongoDB Connector for BI samples can cause the schema-sampling routine to stop functioning by defining a view whose evaluation reliably fails. The sampling logic classifies the resulting server message as transient and, after the configured retries are exhausted, proceeds without a valid result, ending the schema refresh routine. The mongosqld process continues running without a usable schema, so SQL clients are unable to obtain results until an operator removes the view or excludes its namespace from sampling.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
Low
User interaction
None

What an attacker can affect

Confidentiality
None
Integrity
None
Availability
High

Exploit likelihood

0.47%Up 0.2 points since Aug 29, 2026
90%50%10%1%

What each source reports

CVE List Score used 8.3

MongoDB Connector for BI Improper Error Handling During Schema Sampling May Cause Loss of SQL Service

A database user able to create a view in a namespace that MongoDB Connector for BI samples can cause the schema-sampling routine to stop functioning by defining a view whose evaluation reliably fails. The sampling logic classifies the resulting server message as transient and, after the configured retries are exhausted, proceeds without a valid result, ending the schema refresh routine. The mongosqld process continues running without a usable schema, so SQL clients are unable to obtain results until an operator removes the view or excludes its namespace from sampling.

Record
CVE-2026-81490
CVSS 4.0
8.3 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H
CVSS 3.1
7.7 HighCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H
Weakness
CWE-476
Updated
2026-11-02
EUVDEUVD-2026-67931 8.3

A database user able to create a view in a namespace that MongoDB Connector for BI samples can cause the schema-sampling routine to stop functioning by defining a view whose evaluation reliably fails. The sampling logic classifies the resulting server message as transient and, after the configured retries are exhausted, proceeds without a valid result, ending the schema refresh routine. The mongosqld process continues running without a usable schema, so SQL clients are unable to obtain results until an operator removes the view or excludes its namespace from sampling.

Record
EUVD-2026-67931
CVSS 4.0
8.3 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H
Updated
2026-11-02
GitHub AdvisoriesGHSA-g954-97w2-99wv 8.3

A database user able to create a view in a namespace that MongoDB Connector for BI samples can...

A database user able to create a view in a namespace that MongoDB Connector for BI samples can cause the schema-sampling routine to stop functioning by defining a view whose evaluation reliably fails. The sampling logic classifies the resulting server message as transient and, after the configured retries are exhausted, proceeds without a valid result, ending the schema refresh routine. The mongosqld process continues running without a usable schema, so SQL clients are unable to obtain results until an operator removes the view or excludes its namespace from sampling.

Record
GHSA-g954-97w2-99wv
CVSS 4.0
8.3 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
7.7 HighCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H
Weakness
CWE-476
Updated
2026-11-02
NVD 8.3

A database user able to create a view in a namespace that MongoDB Connector for BI samples can cause the schema-sampling routine to stop functioning by defining a view whose evaluation reliably fails. The sampling logic classifies the resulting server message as transient and, after the configured retries are exhausted, proceeds without a valid result, ending the schema refresh routine. The mongosqld process continues running without a usable schema, so SQL clients are unable to obtain results until an operator removes the view or excludes its namespace from sampling.

Record
CVE-2026-81490
CVSS 4.0
8.3 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
7.7 HighCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H
Weakness
CWE-476
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliases, publishedEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2026-81490 is a high vulnerability (CVSS 8.3) in Mongodb Bi Connector, published August 28, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.47%, the 41st percentile. No source names a fixed version.

References

MoveEnter Open