Every CVE Search/ Get API key

CVE-2026-81533

MongoDB BI Connector ODBC Driver Memory-Safety Issue When Parsing Oversized LIMIT Values

6.0 Medium

An application using the MongoDB BI Connector ODBC Driver may encounter a memory-safety issue when a submitted SQL statement contains an unusually long run of digits following a LIMIT clause. The issue occurs only on connections where the driver's optional prefetch setting is enabled, and stems from the driver copying the digit sequence into a fixed-size internal buffer without checking its length. A user able to influence the numeric portion of a LIMIT clause could cause the hosting application process to terminate unexpectedly or corrupt adjacent memory in that process.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
Low
User interaction
None

What an attacker can affect

Confidentiality
None
Integrity
Low
Availability
High

Exploit likelihood

0.37%Up 0.2 points since Aug 29, 2026
90%50%10%1%

What each source reports

CVE List Score used 6.0

MongoDB BI Connector ODBC Driver Memory-Safety Issue When Parsing Oversized LIMIT Values

An application using the MongoDB BI Connector ODBC Driver may encounter a memory-safety issue when a submitted SQL statement contains an unusually long run of digits following a LIMIT clause. The issue occurs only on connections where the driver's optional prefetch setting is enabled, and stems from the driver copying the digit sequence into a fixed-size internal buffer without checking its length. A user able to influence the numeric portion of a LIMIT clause could cause the hosting application process to terminate unexpectedly or corrupt adjacent memory in that process.

Record
CVE-2026-81533
CVSS 4.0
6.0 MediumCVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N
CVSS 3.1
7.1 HighCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H
Weakness
CWE-121
Updated
2026-11-02
EUVDEUVD-2026-67943 6.0

An application using the MongoDB BI Connector ODBC Driver may encounter a memory-safety issue when a submitted SQL statement contains an unusually long run of digits following a LIMIT clause. The issue occurs only on connections where the driver's optional prefetch setting is enabled, and stems from the driver copying the digit sequence into a fixed-size internal buffer without checking its length. A user able to influence the numeric portion of a LIMIT clause could cause the hosting application process to terminate unexpectedly or corrupt adjacent memory in that process.

Record
EUVD-2026-67943
CVSS 4.0
6.0 MediumCVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N
Updated
2026-11-02
GitHub AdvisoriesGHSA-gj6m-p8hr-868g 6.0

An application using the MongoDB BI Connector ODBC Driver may encounter a memory-safety issue...

An application using the MongoDB BI Connector ODBC Driver may encounter a memory-safety issue when a submitted SQL statement contains an unusually long run of digits following a LIMIT clause. The issue occurs only on connections where the driver's optional prefetch setting is enabled, and stems from the driver copying the digit sequence into a fixed-size internal buffer without checking its length. A user able to influence the numeric portion of a LIMIT clause could cause the hosting application process to terminate unexpectedly or corrupt adjacent memory in that process.

Record
GHSA-gj6m-p8hr-868g
CVSS 4.0
6.0 MediumCVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
7.1 HighCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H
Weakness
CWE-121
Updated
2026-11-02
NVD 6.0

An application using the MongoDB BI Connector ODBC Driver may encounter a memory-safety issue when a submitted SQL statement contains an unusually long run of digits following a LIMIT clause. The issue occurs only on connections where the driver's optional prefetch setting is enabled, and stems from the driver copying the digit sequence into a fixed-size internal buffer without checking its length. A user able to influence the numeric portion of a LIMIT clause could cause the hosting application process to terminate unexpectedly or corrupt adjacent memory in that process.

Record
CVE-2026-81533
CVSS 4.0
6.0 MediumCVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
7.1 HighCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H
Weakness
CWE-121
Updated
2026-11-02
OSV 6.0

MongoDB BI Connector ODBC Driver Memory-Safety Issue When Parsing Oversized LIMIT Values

An application using the MongoDB BI Connector ODBC Driver may encounter a memory-safety issue when a submitted SQL statement contains an unusually long run of digits following a LIMIT clause. The issue occurs only on connections where the driver's optional prefetch setting is enabled, and stems from the driver copying the digit sequence into a fixed-size internal buffer without checking its length. A user able to influence the numeric portion of a LIMIT clause could cause the hosting application process to terminate unexpectedly or corrupt adjacent memory in that process.

Record
CVE-2026-81533
CVSS 4.0
6.0 MediumCVSS:4.0/AV:N/AC:L/AT:P/PR:L/UI:N/VC:N/VI:L/VA:H/SC:N/SI:N/SA:N
Weakness
CWE-121
Updated
2026-11-02

Affected products

History

History
RecordedChangedSources
aliases, publishedEUVD
first indexedCVE List, GitHub Advisories, NVD, OSV

Dates are when Every CVE recorded each change. Upstream dates may differ.

In short

CVE-2026-81533 is a medium vulnerability (CVSS 6.0) in Mongodb Bi Connector Odbc Driver, published August 28, 2026. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.37%, the 30th percentile. No source names a fixed version.

References

MoveEnter Open