An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard...

9.8 Critical

CVE-2021-33219 is a critical vulnerability (CVSS 9.8) in Commscope Ruckus Iot Controller, published July 7, 2021. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 2.15%, the 82nd percentile. No source names a fixed version.

What does this mean?
Severity
9.8 CriticalCVSS 3.1, NVD
Exploit chance
2.15%EPSS, 82nd percentile
Exploitation
None knownNot on CISA’s or ENISA’s lists
Fixed in
No fix listedNo source names one

Description

An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard-coded Web Application Administrator Passwords for the admin and nplus1user accounts.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

2.15%Up 1.5 points since Jul 8, 2021
90%50%10%1%

Affected products

What each source reports

NVD Score used9.8

An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard-coded Web Application Administrator Passwords for the admin and nplus1user accounts.

Record
CVE-2021-33219
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
7.5 HighAV:N/AC:L/Au:N/C:P/I:P/A:P
Weakness
CWE-798
Updated
2026-11-02
CVE ListNo score

An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard-coded Web Application Administrator Passwords for the admin and nplus1user accounts.

Record
CVE-2021-33219
Updated
2026-11-02
EUVDEUVD-2021-19931No score

An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard-coded Web Application Administrator Passwords for the admin and nplus1user accounts.

Record
EUVD-2021-19931
Updated
2026-11-03
GitHub AdvisoriesGHSA-34r4-p9qh-fh37No score

An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard...

An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard-coded Web Application Administrator Passwords for the admin and nplus1user accounts.

Record
GHSA-34r4-p9qh-fh37
Weakness
CWE-798
Updated
2026-11-02

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

References

MoveEnter Open