Every CVESearch/Get API key

CVE-2018-20100

An issue was discovered on August Connect devices. Insecure data transfer between the August app...

9.8 Critical

CVE-2018-20100 is a critical vulnerability (CVSS 9.8) in August Connect, published January 2, 2019. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.71%, the 54th percentile. No source names a fixed version.

What does this mean?
Severity
9.8 CriticalCVSS 3.0, NVD
Exploit chance
0.71%EPSS, 54th percentile
Exploitation
None knownNot on CISA’s or ENISA’s lists
Fixed in
No fix listedNo source names one

Description

An issue was discovered on August Connect devices. Insecure data transfer between the August app and August Connect during configuration allows attackers to discover home Wi-Fi credentials. This data transfer uses an unencrypted access point for these credentials, and passes them in an HTTP POST, using the AugustWifiDevice class, with data encrypted with a fixed key found obfuscated in the app.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

0.71%Up 0.3 points since Apr 14, 2021
90%50%10%1%

Affected products

What each source reports

NVD Score used9.8

An issue was discovered on August Connect devices. Insecure data transfer between the August app and August Connect during configuration allows attackers to discover home Wi-Fi credentials. This data transfer uses an unencrypted access point for these credentials, and passes them in an HTTP POST, using the AugustWifiDevice class, with data encrypted with a fixed key found obfuscated in the app.

Record
CVE-2018-20100
CVSS 3.0
9.8 CriticalCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
5.0 MediumAV:N/AC:L/Au:N/C:P/I:N/A:N
Weakness
CWE-311
Updated
2026-11-02
CVE ListNo score

An issue was discovered on August Connect devices. Insecure data transfer between the August app and August Connect during configuration allows attackers to discover home Wi-Fi credentials. This data transfer uses an unencrypted access point for these credentials, and passes them in an HTTP POST, using the AugustWifiDevice class, with data encrypted with a fixed key found obfuscated in the app.

Record
CVE-2018-20100
Updated
2026-11-02
EUVDEUVD-2018-12670No score

An issue was discovered on August Connect devices. Insecure data transfer between the August app and August Connect during configuration allows attackers to discover home Wi-Fi credentials. This data transfer uses an unencrypted access point for these credentials, and passes them in an HTTP POST, using the AugustWifiDevice class, with data encrypted with a fixed key found obfuscated in the app.

Record
EUVD-2018-12670
Updated
2026-11-03
GitHub AdvisoriesGHSA-3j3x-vgx3-q5cg9.8

An issue was discovered on August Connect devices. Insecure data transfer between the August app...

An issue was discovered on August Connect devices. Insecure data transfer between the August app and August Connect during configuration allows attackers to discover home Wi-Fi credentials. This data transfer uses an unencrypted access point for these credentials, and passes them in an HTTP POST, using the AugustWifiDevice class, with data encrypted with a fixed key found obfuscated in the app.

Record
GHSA-3j3x-vgx3-q5cg
CVSS 3.0
9.8 CriticalCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weakness
CWE-311
Updated
2026-11-02

History

History
RecordedChangedSources
facts
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

References

MoveEnter Open