In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions...
CVE-2018-7781 is a high vulnerability (CVSS 8.8) in Schneider Electric Se Pelco Sarix Professional V1, published July 3, 2018. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.59%, the 48th percentile. No source names a fixed version.
- Severity
- 8.8 HighCVSS 3.0, NVD
- Exploit chance
- 0.59%EPSS, 48th percentile
- Exploitation
- None knownNot on CISA’s or ENISA’s lists
- Fixed in
- No fix listedNo source names one
Description
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- Low
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
Affected products
- schneider electric se pelco sarix professional v1
- schneider-electric ibp1110-1er firmware
- schneider-electric ibp219-1er firmware
- schneider-electric ibp319-1er firmware
- schneider-electric ibp519-1er firmware
- schneider-electric ibps110-1er firmware
- schneider-electric imp1110-1 firmware
- schneider-electric imp1110-1e firmware
- schneider-electric imp1110-1er firmware
- schneider-electric imp219-1 firmware
- schneider-electric imp219-1e firmware
- schneider-electric imp219-1er firmware
Show 9 moreShow less
- schneider-electric imp319-1 firmware
- schneider-electric imp319-1e firmware
- schneider-electric imp319-1er firmware
- schneider-electric imp519-1 firmware
- schneider-electric imp519-1e firmware
- schneider-electric imp519-1er firmware
- schneider-electric imps110-1 firmware
- schneider-electric imps110-1e firmware
- schneider-electric imps110-1er firmware
What each source reports
NVD Score used 8.8
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation.
- Record
CVE-2018-7781- CVSS 3.0
- 8.8 High
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 4.0 Medium
AV:N/AC:L/Au:S/C:P/I:N/A:N - Weakness
- CWE-311
- Updated
- 2026-11-02
CVE ListNo score
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation.
- Record
CVE-2018-7781- Updated
- 2026-11-02
EUVDEUVD-2018-19493No score
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation.
- Record
EUVD-2018-19493- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-66q3-3329-6w7w 8.8
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions...
In Schneider Electric Pelco Sarix Professional 1st generation cameras with firmware versions prior to 3.29.69, by sending a specially crafted request an authenticated user can view password in clear text and results in privilege escalation.
- Record
GHSA-66q3-3329-6w7w- CVSS 3.0
- 8.8 High
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-311
- Updated
- 2026-11-02