Every CVESearch/Get API key

CVE-2025-57293

A command injection vulnerability in COMFAST CF-XR11 (firmware V2.7.2) exists in the multi_pppoe...

8.8 High

CVE-2025-57293 is a high vulnerability (CVSS 8.8) in Comfast Cf-xr11 Firmware, published September 18, 2025. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.68%, the 77th percentile. No source names a fixed version.

What does this mean?
Severity
8.8 HighCVSS 3.1, CVE List
Exploit chance
1.68%EPSS, 77th percentile
Exploitation
None knownNot on CISA’s or ENISA’s lists
Fixed in
No fix listedNo source names one

Description

A command injection vulnerability in COMFAST CF-XR11 (firmware V2.7.2) exists in the multi_pppoe API, processed by the sub_423930 function in /usr/bin/webmgnt. The phy_interface parameter is not sanitized, allowing attackers to inject arbitrary commands via a POST request to /cgi-bin/mbox-config?method=SET&section=multi_pppoe. When the action parameter is set to "one_click_redial", the unsanitized phy_interface is used in a system() call, enabling execution of malicious commands. This can lead to unauthorized access to sensitive files, execution of arbitrary code, or full device compromise.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
Required

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

1.68%Up 1.5 points since Sep 19, 2025
90%50%10%1%

Affected products

What each source reports

CVE List Score used8.8

A command injection vulnerability in COMFAST CF-XR11 (firmware V2.7.2) exists in the multi_pppoe API, processed by the sub_423930 function in /usr/bin/webmgnt. The phy_interface parameter is not sanitized, allowing attackers to inject arbitrary commands via a POST request to /cgi-bin/mbox-config?method=SET&section=multi_pppoe. When the action parameter is set to "one_click_redial", the unsanitized phy_interface is used in a system() call, enabling execution of malicious commands. This can lead to unauthorized access to sensitive files, execution of arbitrary code, or full device compromise.

Record
CVE-2025-57293
CVSS 3.1
8.8 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Weakness
CWE-77
Updated
2026-11-02
EUVDEUVD-2025-301978.8

A command injection vulnerability in COMFAST CF-XR11 (firmware V2.7.2) exists in the multi_pppoe API, processed by the sub_423930 function in /usr/bin/webmgnt. The phy_interface parameter is not sanitized, allowing attackers to inject arbitrary commands via a POST request to /cgi-bin/mbox-config?method=SET&section=multi_pppoe. When the action parameter is set to "one_click_redial", the unsanitized phy_interface is used in a system() call, enabling execution of malicious commands. This can lead to unauthorized access to sensitive files, execution of arbitrary code, or full device compromise.

Record
EUVD-2025-30197
CVSS 3.1
8.8 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Updated
2026-11-02
GitHub AdvisoriesGHSA-6x44-8387-hrwg8.8

A command injection vulnerability in COMFAST CF-XR11 (firmware V2.7.2) exists in the multi_pppoe...

A command injection vulnerability in COMFAST CF-XR11 (firmware V2.7.2) exists in the multi_pppoe API, processed by the sub_423930 function in /usr/bin/webmgnt. The phy_interface parameter is not sanitized, allowing attackers to inject arbitrary commands via a POST request to /cgi-bin/mbox-config?method=SET&section=multi_pppoe. When the action parameter is set to "one_click_redial", the unsanitized phy_interface is used in a system() call, enabling execution of malicious commands. This can lead to unauthorized access to sensitive files, execution of arbitrary code, or full device compromise.

Record
GHSA-6x44-8387-hrwg
CVSS 3.1
8.8 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Weakness
CWE-77
Updated
2026-11-02
NVD8.8

A command injection vulnerability in COMFAST CF-XR11 (firmware V2.7.2) exists in the multi_pppoe API, processed by the sub_423930 function in /usr/bin/webmgnt. The phy_interface parameter is not sanitized, allowing attackers to inject arbitrary commands via a POST request to /cgi-bin/mbox-config?method=SET&section=multi_pppoe. When the action parameter is set to "one_click_redial", the unsanitized phy_interface is used in a system() call, enabling execution of malicious commands. This can lead to unauthorized access to sensitive files, execution of arbitrary code, or full device compromise.

Record
CVE-2025-57293
CVSS 3.1
8.8 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Weakness
CWE-77
Updated
2026-11-06

History

History
RecordedChangedSources
factsNVD
first indexedCVE List, EUVD, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

References

MoveEnter Open