Every CVESearch/Get API key

CVE-2017-9961

A vulnerability exists in Schneider Electric's Pro-Face GP Pro EX version 4.07.000 that allows an...

7.8 High

CVE-2017-9961 is a high vulnerability (CVSS 7.8) in Schneider-electric Pro-face Gp Pro Ex, published September 25, 2017. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.38%, the 32nd percentile. No source names a fixed version.

What does this mean?
Severity
7.8 HighCVSS 3.0, NVD
Exploit chance
0.38%EPSS, 32nd percentile
Exploitation
None knownNot on CISA’s or ENISA’s lists
Fixed in
No fix listedNo source names one

Description

A vulnerability exists in Schneider Electric's Pro-Face GP Pro EX version 4.07.000 that allows an attacker to execute arbitrary code. Malicious code installation requires an access to the computer. By placing a specific DLL/OCX file, an attacker is able to force the process to load arbitrary DLL and execute arbitrary code in the context of the process.

Attack profile

How easy it is to exploit

Attack vector
Local
Complexity
Low
Privileges needed
Low
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

0.38%Down 0.7 points since Apr 14, 2021
90%50%10%1%

Affected products

What each source reports

NVD Score used7.8

A vulnerability exists in Schneider Electric's Pro-Face GP Pro EX version 4.07.000 that allows an attacker to execute arbitrary code. Malicious code installation requires an access to the computer. By placing a specific DLL/OCX file, an attacker is able to force the process to load arbitrary DLL and execute arbitrary code in the context of the process.

Record
CVE-2017-9961
CVSS 3.0
7.8 HighCVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
4.6 MediumAV:L/AC:L/Au:N/C:P/I:P/A:P
Updated
2026-11-02
CVE ListNo score

A vulnerability exists in Schneider Electric's Pro-Face GP Pro EX version 4.07.000 that allows an attacker to execute arbitrary code. Malicious code installation requires an access to the computer. By placing a specific DLL/OCX file, an attacker is able to force the process to load arbitrary DLL and execute arbitrary code in the context of the process.

Record
CVE-2017-9961
Updated
2026-11-02
EUVDEUVD-2017-18870No score

A vulnerability exists in Schneider Electric's Pro-Face GP Pro EX version 4.07.000 that allows an attacker to execute arbitrary code. Malicious code installation requires an access to the computer. By placing a specific DLL/OCX file, an attacker is able to force the process to load arbitrary DLL and execute arbitrary code in the context of the process.

Record
EUVD-2017-18870
Updated
2026-11-03
GitHub AdvisoriesGHSA-9g55-3rhr-jqqq7.8

A vulnerability exists in Schneider Electric's Pro-Face GP Pro EX version 4.07.000 that allows an...

A vulnerability exists in Schneider Electric's Pro-Face GP Pro EX version 4.07.000 that allows an attacker to execute arbitrary code. Malicious code installation requires an access to the computer. By placing a specific DLL/OCX file, an attacker is able to force the process to load arbitrary DLL and execute arbitrary code in the context of the process.

Record
GHSA-9g55-3rhr-jqqq
CVSS 3.0
7.8 HighCVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Updated
2026-11-02

History

History
RecordedChangedSources
facts
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

References

MoveEnter Open