Every CVESearch/Get API key

CVE-2024-29082

Vonets WiFi Bridges Improper Access Control

8.8 High

CVE-2024-29082 is a high vulnerability (CVSS 8.8) in Vonets Vap11ac, published August 8, 2024. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.80%, the 57th percentile. No source names a fixed version.

What does this mean?
Severity
8.8 HighCVSS 4.0, CVE List
Exploit chance
0.80%EPSS, 57th percentile
Exploitation
None knownNot on CISA’s or ENISA’s lists
Fixed in
No fix listedNo source names one

Description

Improper access control vulnerability affecting Vonets

industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enables an unauthenticated remote attacker to bypass authentication and factory reset the device via unprotected goform endpoints.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
Low
Integrity
Low
Availability
High

Exploit likelihood

0.80%Up 0.8 points since Aug 13, 2024
90%50%10%1%

Affected products

Show 16 moreShow less

What each source reports

CVE List Score used8.8

Vonets WiFi Bridges Improper Access Control

Improper access control vulnerability affecting Vonets

industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enables an unauthenticated remote attacker to bypass authentication and factory reset the device via unprotected goform endpoints.

Record
CVE-2024-29082
CVSS 4.0
8.8 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N
CVSS 3.1
8.6 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H
Weakness
CWE-284
Updated
2026-11-02
EUVDEUVD-2024-344398.8

Improper access control vulnerability affecting Vonets

industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enables an unauthenticated remote attacker to bypass authentication and factory reset the device via unprotected goform endpoints.

Record
EUVD-2024-34439
CVSS 4.0
8.8 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N
Updated
2026-11-03
GitHub AdvisoriesGHSA-fx2m-xj8m-g5xr8.8

Improper access control vulnerability affecting Vonets industrial wifi bridge relays and wifi...

Improper access control vulnerability affecting Vonets

industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enables an unauthenticated remote attacker to bypass authentication and factory reset the device via unprotected goform endpoints.

Record
GHSA-fx2m-xj8m-g5xr
CVSS 4.0
8.8 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
8.6 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H
Weakness
CWE-284
Updated
2026-11-02
NVD8.8

Improper access control vulnerability affecting Vonets

industrial wifi bridge relays and wifi bridge repeaters, software versions 3.3.23.6.9 and prior, enables an unauthenticated remote attacker to bypass authentication and factory reset the device via unprotected goform endpoints.

Record
CVE-2024-29082
CVSS 4.0
8.8 HighCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1
8.6 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H
CVSS 3.1
8.6 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H
Weakness
CWE-284
Updated
2026-11-02

History

History
RecordedChangedSources
aliases, publishedEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.