CVE-2017-14006
GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are...
CVE-2017-14006 is a critical vulnerability (CVSS 9.8) in Ge Xeleris, published March 20, 2018. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.86%, the 79th percentile. No source names a fixed version.
- Severity
- 9.8 CriticalCVSS 3.0, NVD
- Exploit chance
- 1.86%EPSS, 79th percentile
- Exploitation
- None knownNot on CISA’s or ENISA’s lists
- Fixed in
- No fix listedNo source names one
Description
GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
Affected products
What each source reports
NVD Score used 9.8
GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
- Record
CVE-2017-14006- CVSS 3.0
- 9.8 Critical
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 7.5 High
AV:N/AC:L/Au:N/C:P/I:P/A:P - Weakness
- CWE-287, CWE-798
- Updated
- 2026-11-02
CVE ListNo score
GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
- Record
CVE-2017-14006- Weakness
- CWE-287
- Updated
- 2026-11-02
EUVDEUVD-2017-5521No score
GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
- Record
EUVD-2017-5521- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-ghg8-72p6-f85w 9.8
GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are...
GE Xeleris versions 1.0,1.1,2.1,3.0,3.1, medical imaging systems, all current versions are affected, these devices use default or hard-coded credentials. Successful exploitation of this vulnerability may allow a remote attacker to bypass authentication and gain access to the affected devices.
- Record
GHSA-ghg8-72p6-f85w- CVSS 3.0
- 9.8 Critical
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-798
- Updated
- 2026-11-02
History
| Recorded | Changed | Sources |
|---|---|---|
| facts | ||
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.