Every CVESearch/Get API key

CVE-2013-0108

An ActiveX control in HscRemoteDeploy.dll in Honeywell Enterprise Buildings Integrator (EBI) R310...

6.8 MediumPublic exploit

CVE-2013-0108 is a medium vulnerability (CVSS 6.8) in Honeywell Enterprise Buildings Integrator, published February 24, 2013. Public exploit code exists. EPSS puts the chance of exploitation in the next 30 days at 26.6%, the 98th percentile. No source names a fixed version.

What does this mean?
Severity
6.8 MediumCVSS 2.0, NVD
Exploit chance
26.6%EPSS, 98th percentile
Exploitation
None known2 public exploits
Fixed in
No fix listedNo source names one

Description

An ActiveX control in HscRemoteDeploy.dll in Honeywell Enterprise Buildings Integrator (EBI) R310, R400.2, R410.1, and R410.2; SymmetrE R310, R410.1, and R410.2; ComfortPoint Open Manager (aka CPO-M) Station R100; and HMIWeb Browser client packages allows remote attackers to execute arbitrary code via a crafted HTML document.

Exploit likelihood

26.6%Down 48.1 points since Feb 4, 2022
90%50%10%1%

Affected products

Public exploits

Links only. Every CVE stores no exploit code.

What each source reports

NVD Score used6.8

An ActiveX control in HscRemoteDeploy.dll in Honeywell Enterprise Buildings Integrator (EBI) R310, R400.2, R410.1, and R410.2; SymmetrE R310, R410.1, and R410.2; ComfortPoint Open Manager (aka CPO-M) Station R100; and HMIWeb Browser client packages allows remote attackers to execute arbitrary code via a crafted HTML document.

Record
CVE-2013-0108
CVSS 2.0
6.8 MediumAV:N/AC:M/Au:N/C:P/I:P/A:P
Weakness
CWE-94
Updated
2026-11-02
CVE ListNo score

An ActiveX control in HscRemoteDeploy.dll in Honeywell Enterprise Buildings Integrator (EBI) R310, R400.2, R410.1, and R410.2; SymmetrE R310, R410.1, and R410.2; ComfortPoint Open Manager (aka CPO-M) Station R100; and HMIWeb Browser client packages allows remote attackers to execute arbitrary code via a crafted HTML document.

Record
CVE-2013-0108
Updated
2026-11-02
EUVDEUVD-2013-0151No score

An ActiveX control in HscRemoteDeploy.dll in Honeywell Enterprise Buildings Integrator (EBI) R310, R400.2, R410.1, and R410.2; SymmetrE R310, R410.1, and R410.2; ComfortPoint Open Manager (aka CPO-M) Station R100; and HMIWeb Browser client packages allows remote attackers to execute arbitrary code via a crafted HTML document.

Record
EUVD-2013-0151
Updated
2026-11-03
GitHub AdvisoriesGHSA-gqjf-wvw9-g6pmNo score

An ActiveX control in HscRemoteDeploy.dll in Honeywell Enterprise Buildings Integrator (EBI) R310...

An ActiveX control in HscRemoteDeploy.dll in Honeywell Enterprise Buildings Integrator (EBI) R310, R400.2, R410.1, and R410.2; SymmetrE R310, R410.1, and R410.2; ComfortPoint Open Manager (aka CPO-M) Station R100; and HMIWeb Browser client packages allows remote attackers to execute arbitrary code via a crafted HTML document.

Record
GHSA-gqjf-wvw9-g6pm
Weakness
CWE-94
Updated
2026-11-02

History

History
RecordedChangedSources
exploits, facts
aliasesEUVD
first indexedCVE List, Exploit-DB, GitHub Advisories, Metasploit, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

References

MoveEnter Open