CVE-2017-3195
Commvault Edge Communication Service (cvd) prior to version 11 SP7 or version 11 SP6 with hotfix...
CVE-2017-3195 is a critical vulnerability (CVSS 9.8) in Commvault Edge, published December 15, 2017. Public exploit code exists. EPSS puts the chance of exploitation in the next 30 days at 21.4%, the 97th percentile. No source names a fixed version.
- Severity
- 9.8 CriticalCVSS 3.1, NVD
- Exploit chance
- 21.4%EPSS, 97th percentile
- Exploitation
- None known1 public exploit
- Fixed in
- No fix listedNo source names one
Description
Commvault Edge Communication Service (cvd) prior to version 11 SP7 or version 11 SP6 with hotfix 590 is prone to a stack-based buffer overflow vulnerability that could lead to arbitrary code execution with administrative privileges.
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- High
- Integrity
- High
- Availability
- High
Exploit likelihood
Affected products
Public exploits
Links only. Every CVE stores no exploit code.
| Source | Link | Date |
|---|---|---|
| Exploit-DB | CommVault Edge 11 SP6 - Stack Buffer Overflow (PoC) | 2017-03-16 |
What each source reports
NVD Score used 9.8
Commvault Edge Communication Service (cvd) prior to version 11 SP7 or version 11 SP6 with hotfix 590 is prone to a stack-based buffer overflow vulnerability that could lead to arbitrary code execution with administrative privileges.
- Record
CVE-2017-3195- CVSS 3.1
- 9.8 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - CVSS 2.0
- 10.0 High
AV:N/AC:L/Au:N/C:C/I:C/A:C - Weakness
- CWE-121, CWE-119
- Updated
- 2026-11-02
CVE ListNo score
Commvault Edge Communication Service (cvd) prior to version 11 SP7 or version 11 SP6 with hotfix 590 is prone to a stack-based buffer overflow vulnerability that could lead to arbitrary code execution with administrative privileges.
- Record
CVE-2017-3195- Weakness
- CWE-121
- Updated
- 2026-11-02
EUVDEUVD-2017-12321No score
Commvault Edge Communication Service (cvd) prior to version 11 SP7 or version 11 SP6 with hotfix 590 is prone to a stack-based buffer overflow vulnerability that could lead to arbitrary code execution with administrative privileges.
- Record
EUVD-2017-12321- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-h4f8-5wh7-64hg 9.8
Commvault Edge Communication Service (cvd) prior to version 11 SP7 or version 11 SP6 with hotfix...
Commvault Edge Communication Service (cvd) prior to version 11 SP7 or version 11 SP6 with hotfix 590 is prone to a stack-based buffer overflow vulnerability that could lead to arbitrary code execution with administrative privileges.
- Record
GHSA-h4f8-5wh7-64hg- CVSS 3.1
- 9.8 Critical
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H - Weakness
- CWE-119, CWE-121
- Updated
- 2026-11-02
History
| Recorded | Changed | Sources |
|---|---|---|
| facts | ||
| aliases | EUVD | |
| first indexed | CVE List, Exploit-DB, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.