Every CVESearch/Get API key

CVE-2019-5617

C4G BLIS Improper Access Control

10.0 Critical

CVE-2019-5617 is a critical vulnerability (CVSS 10.0) in C4g Basic Laboratory Information System, published November 6, 2019. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.32%, the 71st percentile. No source names a fixed version.

What does this mean?
Severity
10.0 CriticalCVSS 3.1, CVE List
Exploit chance
1.32%EPSS, 71st percentile
Exploitation
None knownNot on CISA’s or ENISA’s lists
Fixed in
No fix listedNo source names one

Description

Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

1.32%Up 0.9 points since Apr 14, 2021
90%50%10%1%

Affected products

What each source reports

CVE List Score used10.0

C4G BLIS Improper Access Control

Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.

Record
CVE-2019-5617
CVSS 3.1
10.0 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Weakness
CWE-284
Updated
2026-11-02
EUVDEUVD-2019-1519210.0

Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.

Record
EUVD-2019-15192
CVSS 3.1
10.0 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
Updated
2026-11-03
GitHub AdvisoriesGHSA-jj7f-f2vq-pvc7No score

Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and...

Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.

Record
GHSA-jj7f-f2vq-pvc7
Weakness
CWE-306
Updated
2026-11-02
NVD10.0

Computing For Good's Basic Laboratory Information System (also known as C4G BLIS) version 3.4 and earlier suffers from an instance of CWE-284, "Improper Access Control." As a result, an unauthenticated user may change the password of any administrator-level user.

Record
CVE-2019-5617
CVSS 3.1
10.0 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
CVSS 3.1
9.8 CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
7.5 HighAV:N/AC:L/Au:N/C:P/I:P/A:P
Weakness
CWE-284, CWE-306
Updated
2026-11-02

History

History
RecordedChangedSources
facts
aliases, products, publishedEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

References

MoveEnter Open