CVE-2017-9851
** DISPUTED ** An issue was discovered in SMA Solar Technology products. By sending nonsense data...
CVE-2017-9851 is a high vulnerability (CVSS 7.5) in Sma Sunny Explorer, published August 5, 2017. Its validity is disputed. EPSS puts the chance of exploitation in the next 30 days at 1.86%, the 79th percentile.
- Severity
- 7.5 HighCVSS 3.0, NVD
- Exploit chance
- 1.86%EPSS, 79th percentile
- Exploitation
- None knownNot on CISA’s or ENISA’s lists
- Fixed in
- No fix listedNo source names one
Description
An issue was discovered in SMA Solar Technology products. By sending nonsense data or setting up a TELNET session to the database port of Sunny Explorer, the application can be crashed. NOTE: the vendor reports that the maximum possible damage is a communication failure. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
Attack profile
How easy it is to exploit
- Attack vector
- Network
- Complexity
- Low
- Privileges needed
- None
- User interaction
- None
What an attacker can affect
- Confidentiality
- None
- Integrity
- None
- Availability
- High
Exploit likelihood
Affected products
What each source reports
NVD Score used 7.5
An issue was discovered in SMA Solar Technology products. By sending nonsense data or setting up a TELNET session to the database port of Sunny Explorer, the application can be crashed. NOTE: the vendor reports that the maximum possible damage is a communication failure. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
- Record
CVE-2017-9851- CVSS 3.0
- 7.5 High
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - CVSS 2.0
- 5.0 Medium
AV:N/AC:L/Au:N/C:N/I:N/A:P - Updated
- 2026-11-02
CVE ListNo score
An issue was discovered in SMA Solar Technology products. By sending nonsense data or setting up a TELNET session to the database port of Sunny Explorer, the application can be crashed. NOTE: the vendor reports that the maximum possible damage is a communication failure. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
- Record
CVE-2017-9851- Updated
- 2026-11-02
EUVDEUVD-2017-18761No score
An issue was discovered in SMA Solar Technology products. By sending nonsense data or setting up a TELNET session to the database port of Sunny Explorer, the application can be crashed. NOTE: the vendor reports that the maximum possible damage is a communication failure. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected
- Record
EUVD-2017-18761- Updated
- 2026-11-03
GitHub AdvisoriesGHSA-r4c9-h547-774j 7.5
** DISPUTED ** An issue was discovered in SMA Solar Technology products. By sending nonsense data...
** DISPUTED ** An issue was discovered in SMA Solar Technology products. By sending nonsense data or setting up a TELNET session to the database port of Sunny Explorer, the application can be crashed. NOTE: the vendor reports that the maximum possible damage is a communication failure. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected.
- Record
GHSA-r4c9-h547-774j- CVSS 3.0
- 7.5 High
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H - Updated
- 2026-11-02
History
| Recorded | Changed | Sources |
|---|---|---|
| facts | ||
| aliases | EUVD | |
| first indexed | CVE List, GitHub Advisories, NVD |
Dates are when Every CVE recorded each change. Upstream dates may differ.