Every CVESearch/Get API key

CVE-2017-11506

When linking a Nessus scanner or agent to Tenable.io or other manager, Nessus 6.x before 6.11...

7.4 High

CVE-2017-11506 is a high vulnerability (CVSS 7.4) in Tenable Nessus, published August 9, 2017. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 0.57%, the 47th percentile. No source names a fixed version.

What does this mean?
Severity
7.4 HighCVSS 3.0, NVD
Exploit chance
0.57%EPSS, 47th percentile
Exploitation
None knownNot on CISA’s or ENISA’s lists
Fixed in
No fix listedNo source names one

Description

When linking a Nessus scanner or agent to Tenable.io or other manager, Nessus 6.x before 6.11 does not verify the manager's TLS certificate when making the initial outgoing connection. This could allow man-in-the-middle attacks.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
High
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
None

Exploit likelihood

0.57%Down 0.1 points since Apr 14, 2021
90%50%10%1%

Affected products

What each source reports

NVD Score used7.4

When linking a Nessus scanner or agent to Tenable.io or other manager, Nessus 6.x before 6.11 does not verify the manager's TLS certificate when making the initial outgoing connection. This could allow man-in-the-middle attacks.

Record
CVE-2017-11506
CVSS 3.0
7.4 HighCVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N
CVSS 2.0
5.8 MediumAV:N/AC:M/Au:N/C:P/I:P/A:N
Weakness
CWE-295
Updated
2026-11-02
CVE ListNo score

When linking a Nessus scanner or agent to Tenable.io or other manager, Nessus 6.x before 6.11 does not verify the manager's TLS certificate when making the initial outgoing connection. This could allow man-in-the-middle attacks.

Record
CVE-2017-11506
Updated
2026-11-02
EUVDEUVD-2017-3123No score

When linking a Nessus scanner or agent to Tenable.io or other manager, Nessus 6.x before 6.11 does not verify the manager's TLS certificate when making the initial outgoing connection. This could allow man-in-the-middle attacks.

Record
EUVD-2017-3123
Updated
2026-11-03
GitHub AdvisoriesGHSA-rgmc-q3r4-jxvv7.4

When linking a Nessus scanner or agent to Tenable.io or other manager, Nessus 6.x before 6.11...

When linking a Nessus scanner or agent to Tenable.io or other manager, Nessus 6.x before 6.11 does not verify the manager's TLS certificate when making the initial outgoing connection. This could allow man-in-the-middle attacks.

Record
GHSA-rgmc-q3r4-jxvv
CVSS 3.0
7.4 HighCVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N
Weakness
CWE-295
Updated
2026-11-02

History

History
RecordedChangedSources
facts
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

References

MoveEnter Open