Every CVESearch/Get API key

CVE-2018-8848

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software, upon...

7.5 High

CVE-2018-8848 is a high vulnerability (CVSS 7.5) in Philips E-alert Unit (non-medical Device), published September 26, 2018. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 2.03%, the 81st percentile. No source names a fixed version.

What does this mean?
Severity
7.5 HighCVSS 3.1, NVD
Exploit chance
2.03%EPSS, 81st percentile
Exploitation
None knownNot on CISA’s or ENISA’s lists
Fixed in
No fix listedNo source names one

Description

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor.

Attack profile

How easy it is to exploit

Attack vector
Network
Complexity
Low
Privileges needed
None
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
None
Availability
None

Exploit likelihood

2.03%Up 1.2 points since Apr 14, 2021
90%50%10%1%

Affected products

What each source reports

NVD Score used7.5

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor.

Record
CVE-2018-8848
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
CVSS 2.0
5.0 MediumAV:N/AC:L/Au:N/C:P/I:N/A:N
Weakness
CWE-276, CWE-732
Updated
2026-11-02
CVE ListNo score

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor.

Record
CVE-2018-8848
Weakness
CWE-276
Updated
2026-11-02
EUVDEUVD-2018-20456No score

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor.

Record
EUVD-2018-20456
Updated
2026-11-03
GitHub AdvisoriesGHSA-rvgx-rpj5-2pcr7.5

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software, upon...

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended actor.

Record
GHSA-rvgx-rpj5-2pcr
CVSS 3.1
7.5 HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Weakness
CWE-732
Updated
2026-11-02

History

History
RecordedChangedSources
facts
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

References

MoveEnter Open