Every CVESearch/Get API key

CVE-2012-5864

Sinapsi eSolar Improper Authentication

9.4 Public exploit

CVE-2012-5864 is a vulnerability (CVSS 9.4) in Sinapsi Esolar, published November 23, 2012. Public exploit code exists. EPSS puts the chance of exploitation in the next 30 days at 4.91%, the 92nd percentile. No source names a fixed version.

What does this mean?
Severity
9.4 CVSS 2.0, CVE List
Exploit chance
4.91%EPSS, 92nd percentile
Exploitation
None known1 public exploit
Fixed in
No fix listedNo source names one

Description

These Sinapsi devices do not check if users that visit pages within the device have properly authenticated. By directly visiting the pages within the device, attackers can gain unauthorized access with administrative privileges.

Exploit likelihood

4.91%Up 3.7 points since Feb 4, 2022
90%50%10%1%

Affected products

Public exploits

Links only. Every CVE stores no exploit code.

Public exploits
SourceLinkDate
Exploit-DBEzylog Photovoltaic Management Server - Multiple Vulnerabilities2012-09-12

What each source reports

CVE List Score used9.4

Sinapsi eSolar Improper Authentication

These Sinapsi devices do not check if users that visit pages within the device have properly authenticated. By directly visiting the pages within the device, attackers can gain unauthorized access with administrative privileges.

Record
CVE-2012-5864
CVSS 2.0
9.4 AV:N/AC:L/Au:N/C:C/I:C/A:N
Weakness
CWE-287
Updated
2026-11-02
EUVDEUVD-2012-57429.4

These Sinapsi devices do not check if users that visit pages within the device have properly authenticated. By directly visiting the pages within the device, attackers can gain unauthorized access with administrative privileges.

Record
EUVD-2012-5742
CVSS 2.0
9.4 CriticalAV:N/AC:L/Au:N/C:C/I:C/A:N
Updated
2026-11-02
GitHub AdvisoriesGHSA-v26h-2hg9-6mq7No score

The management web pages on the Sinapsi eSolar Light Photovoltaic System Monitor (aka Schneider...

The management web pages on the Sinapsi eSolar Light Photovoltaic System Monitor (aka Schneider Electric Ezylog photovoltaic SCADA management server), Sinapsi eSolar, and Sinapsi eSolar DUO with firmware before 2.0.2870_2.2.12 do not require authentication, which allows remote attackers to obtain administrative access via a direct request, as demonstrated by a request to ping.php.

Record
GHSA-v26h-2hg9-6mq7
Weakness
CWE-287
Updated
2026-11-02
NVD9.4

These Sinapsi devices do not check if users that visit pages within the device have properly authenticated. By directly visiting the pages within the device, attackers can gain unauthorized access with administrative privileges.

Record
CVE-2012-5864
CVSS 2.0
9.4 HighAV:N/AC:L/Au:N/C:C/I:C/A:N
CVSS 2.0
10.0 HighAV:N/AC:L/Au:N/C:C/I:C/A:C
Weakness
CWE-287, CWE-264
Updated
2026-11-02

History

History
RecordedChangedSources
facts
aliasesEUVD
first indexedCVE List, Exploit-DB, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

References

MoveEnter Open