Every CVESearch/Get API key

CVE-2021-45596

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects...

8.4 High

CVE-2021-45596 is a high vulnerability (CVSS 8.4) in Netgear Cbr750 Firmware, published December 26, 2021. No source lists public exploit code. EPSS puts the chance of exploitation in the next 30 days at 1.53%, the 75th percentile. No source names a fixed version.

What does this mean?
Severity
8.4 HighCVSS 3.1, CVE List
Exploit chance
1.53%EPSS, 75th percentile
Exploitation
None knownNot on CISA’s or ENISA’s lists
Fixed in
No fix listedNo source names one

Description

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.

Attack profile

How easy it is to exploit

Attack vector
Adjacent network
Complexity
Low
Privileges needed
High
User interaction
None

What an attacker can affect

Confidentiality
High
Integrity
High
Availability
High

Exploit likelihood

1.53%Up 1.1 points since Dec 26, 2021
90%50%10%1%

Affected products

What each source reports

CVE List Score used8.4

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.

Record
CVE-2021-45596
CVSS 3.1
8.4 HighCVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N
Updated
2026-11-02
EUVDEUVD-2021-323628.4

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.

Record
EUVD-2021-32362
CVSS 3.1
8.4 HighCVSS:3.1/AC:L/AV:A/A:H/C:H/I:H/PR:H/S:C/UI:N
Updated
2026-11-03
GitHub AdvisoriesGHSA-v3vh-3r83-h3r3No score

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects...

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.

Record
GHSA-v3vh-3r83-h3r3
Weakness
CWE-77
Updated
2026-11-02
NVD8.4

Certain NETGEAR devices are affected by command injection by an authenticated user. This affects CBR750 before 4.6.3.6, RBK752 before 3.2.17.12, RBR750 before 3.2.17.12, RBS750 before 3.2.17.12, RBK852 before 3.2.17.12, RBR850 before 3.2.17.12, and RBS850 before 3.2.17.12.

Record
CVE-2021-45596
CVSS 3.1
8.4 HighCVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
CVSS 3.1
8.8 HighCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0
6.5 MediumAV:N/AC:L/Au:S/C:P/I:P/A:P
Weakness
CWE-77
Updated
2026-11-02

History

History
RecordedChangedSources
aliasesEUVD
first indexedCVE List, GitHub Advisories, NVD

Dates are when Every CVE recorded each change. Upstream dates may differ.

References

MoveEnter Open